Infrared Temperature Measurement in Plastic Processing
KKInstruments offers a wide variety of infrared thermometers that monitor and control temperature in plastics manufacturing processes. These industrial temperature sensors monitor fast moving processes quickly and efficiently. They measure the temperature of the product directly, instead of the oven or the dryer, allowing you to quickly adjust process parameters to ensure top product quality.
Products
Infrared thermometers (Fix-Type/In-Situ)
Name | SKU | Description | Category | ||
---|---|---|---|---|---|
GNA3100A-SS-1004V2 800~2400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Two color Non-Contact Fixed Infrared Thermometer SS-100 two color(Si/Si) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 800 ℃ to maximum 2400℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. | Thermometers |
|
||
GNA3101A-2IGA-1004V2 400~1200C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Two color Non-Contact Fixed Infrared Thermometer 2IGA-100 two color(InGaAs/InGaAs) non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 400 ℃ to maximum 1200℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. | Thermometers |
|
||
GNA3102A-IR-804V2 500~1700C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Non-Contact Fixed Infrared Thermometer IR-80 non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 500 ℃ to maximum 1700℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. IR-80 is composed of sensor & controller. The measurement temperature displays... | Thermometers |
|
||
GNA3103A-IR-80-H4V2 500~1700C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Non-Contact Fixed Infrared Thermometer IR-80-H non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 500 ℃ to maximum 1700℃ in the distance of 80:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. | Thermometers |
|
||
GNA3104A-IR-404V2 0~1000C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Non-Contact Fixed Infrared Thermometer IR-40 non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from -20 ℃ to maximum 1000℃ in the distance of 40:1 D:S (Distance to Spot). Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target. | Thermometers |
|
||
GNA3105A-IR-214V2 0~400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Non-Contact Fixed Infrared Thermometer non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) or RS-485 communication signal output. It can measure from 0 ℃ to maximum 400℃ in the distance of 12:1 D:S(Distance to Spot). | Thermometers |
|
||
GNA3106A-IR-204v2 0~400C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Non-Contact Fixed Infrared Thermometer non-contact infrared thermometer measures the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA). It can measure from 0 ℃ to maximum 400℃ in the distance of 10:1 D:S (Distance to Spot). Emissivity is 0.95 (fixed). | Thermometers |
|
||
GNA3107A-6-IRMAN -20~600C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Non-Contact Fixed Infrared Thermometer non-contact infrared thermometer measures the amount of infrared energy emitted from object and transmits standard current output signal (4~20mA) or RS-485 communication output signal. Also, it transmits relay contacts for alarm signal. As 6-IRman is composed of infrared sensor head & LCD display with keypad, you can check the temperature value in real-time at the installation site. You can measure the temperature ranged from -20 to max. 600℃... | Thermometers |
|
||
GNA3108A-10-IRMAN -20~1000C INSTALLATION-TYPE INFRARED THERMOMETER OUTPUT:4~20MA | Measuring range -20~1000℃,Spectral range 8~14㎛,optics 40:1,emissivity 0.10 ~ 0.99 adjustable, output 0~20mA/4~20mA/1~5V& 3m cable. PC software provided | Thermometers |
|
||
GNA3200-COMPACT MULTI ANALOG INPUT INDICATOR | Multi-input indicator has built-in high performance A/D converter & micro-processor which enable multi input signals, output signal transmission, communication, and alarm | Thermometers |
|
||
GNA3201-L-SHAPE ANGLE ADJUSTABLE BRACKET | Bracket is to fix infrared thermometer. | Thermometers |
|
||
GNA3202-Air Purge Jacket | Air purge removes dust around infrared thermometer. It can be applicable to IR-20, IR-20-4W, IR-21, IR-40, IR-80, IR-80-H, 6-IRman, SS-100, 2IGA-100 | Thermometers |
|
||
GNA3203-AIR/WATER COOLING JACKET FOR IR-40, IR-80, IR-80-H, 10-IRMAN, 6-IRMAN | Water-cooling jacket is to use under the high temperature environment. It makes infrared thermometer cool down and working properly. It can be applicable to IR-40, IR-80, IR-80-H, SS-100, 2IGA-100 | Thermometers |
|
||
GNA3204-AIR/WATER COOLING JACKET FOR SS-100, 2IGA-100 | AIR/WATER COOLING JACKET FOR SS-100, 2IGA-100 | Thermometers |
|
||
GNA3205-2INCH LED DISPLAY | GNA3205-2INCH LED DISPLAY | Thermometers |
|
||
Calex PyroCouple Infra Red Temperature Sensor | •Temperature range: -20°C to 500°C •Emissivity setting: fixed at 0.95 •Two-wire 4-20 mA output or four-wire voltage/thermocouple output •Four-wire unit also provides internal sensor temperature •Field of view: 2:1, 15:1, 30:1 or close focus •Fast response with high stability •Stainless steel housing, sealed to IP65 •Quick and easy installation • Optional air/water cooled housing, air purge collar, laser sighting tool and mounting brackets | Infrared thermometers (Portable/Handheld) |
|