DKK- TOA CLD-7M
|
|
Measures chloride demand of water and estimates chlorine injection level; best suited for feed forward control
Meas. range
From 0 - 5 mg/L to 10 mg/L (ppm) From 0 - 10 mg/L to 20 mg/L (ppm)
|
Chloride Demand Analyzer
|
|
|
DKK- TOA CLF-1610
|
|
Measures free residual chlorine of clean water continuously with the reagentless polarographic method
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 1/2, 0 - 1/3, 0 - 2/3 mg/L (ppm) (2-range)
|
Reagentless Free Chlorine Analyzer
|
|
|
DKK-TOA A5/A6 Series
|
|
Hermetically sealed 2-electrode type detector featured with excellent heat-proofing and pressure tightness
Pipeline-insertion/immersion/flow-through/throw-in/leadless, etc. type available
Four types of cell constants available: 0.01, 0.1, 1.0, 10 cm-1
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Industrial Conductivity Detector
|
|
|
DKK-TOA AA-1(for Standard) / AA-2 (for Ultrapure Water)
|
|
Single-function (no indication) conductivity analyzer for field installation
Easy installation for the one-unit amplifier and detector
Output: 4 - 20mADC
Power supply: 100VAC
Meas. range
AA-1: 0 - 2 μS/cm to 0 - 10000 μS/cm AA-2: 0 - 0.2/0.5/1.0 μS/cm
|
Conductivity Detectors with Amplifier
|
|
|
DKK-TOA ABT-511
|
|
Automatic Burette ABT-511
Precising dispensing system (stable quantitation and speed)
Titration burette (manual titration) supported
GLP compliance
Sampling mode loaded(measure/dilution)
RS-232 equipped as standard specification
|
Automatic Titrator
|
|
|
DKK-TOA AF-100
|
|
Enables bacteria and cell measurements in 50 sec.
Highly sensitive measurement at 1 - 1000 cells/mL level
Enables direct measurement of membrane filter
Compliant to sanitary management by swap test
Useful functions such as ATP concentration and cell converted value available
Automatic reagent dispenser is optional (DF-10 sold separately)
|
ATP Analyzer
|
|
|
DKK-TOA ALF-1600
|
|
Continuous measurement of alkalinity data in water purification process by coulometric titration method
Requires only 1/4 reagent volume of existing model
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 50/100 mg/L (ppm) (2-ranges)
|
Alkalinity Analyzer
|
|
|
DKK-TOA AQM-100A
|
|
Resistivity Analyzer for Ultra-Pure Water AQM-100A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA AQM-210A
|
|
Panel Type Resistivity Analyzer AQM-210A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
RS-232 equipped as standard specification
Output: 2-channel, insulated, 4 - 20mA
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA AR4/AR5 Series
|
|
Compact 2-electrode type (titanium) detector designed for ultrapure water
Pipeline insertion type, leadless type
Two types of cell constants available: 0.01, 0.1 cm-1
Meas. range
0 - 20/200 MΩ·cm 0 - 0.2/2 μS/cm
|
Industrial Conductivity Detector
|
|
|
DKK-TOA AUT-701
|
|
Dual system allows for 2-channel simultaneous titration
Strong&Float high performance electrodes
USB(Host) and LAN equipped as standard specification
Validation supporting function
Turntable, auto-sampling system and etc. connectable
|
Automatic Titrator
|
|
|
DKK-TOA BHC-7C
|
|
Immersion Type pH/ORP Detector with Brush Cleaner BHC-7C
Immersion type pH/ORP electrode holder with cleaning brush (BHC-7C)
The swing movements wash the electrode tip and prevent it from fouling
One-touch detachable holder and easy maintenance
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA BMR-24
|
|
Compact and lightweight model in accordance with DIN standard
DC 24V power supply designed for 4-point alarm and 2-wire transmitters
Often used as a receiver of 2-wire or 4-wire transmitter (such as pH/ORP meters, conductivity analyzers and DO meters)
Meas. range
pH meter: pH; 0 - 14 70divisions (to be specified otherwise)
|
Bar Graph Meter Relay
|
|
|
DKK-TOA BPM-2000
|
|
Designed for oil refinery
Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc.
Adopts high resolution liquid level detecting sensor
Newly-developed FA computer embedded with large-sized, color touch panel
Explosion-proof TIIS fd2G4 certified
Meas. range
Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C)
|
Boiling Point Analyzer
|
|
|
DKK-TOA BSC
|
|
A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers
Enables sampling for analysis from the boiler
Consistent manufacturing from analyzer to sampler
Sample condition
Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min
|
Boiler Sampling System
|
|
|
DKK-TOA CD-36D/38D
|
|
Measures free residual chlorine of chlorinated samples from purification/food processing/semiconductor plants and pool without reagent
Continuous measurement by polarographic method
Meas. range
CD-36D: 0 - 2 mg/L (ppm) CD-38D: 0 - 100 mg/L (ppm)
|
Reagentless Free Chlorine Analyzer
|
|
|
DKK-TOA CFPP
|
|
Designed for oil refinery
Continuous measurement of plugging pour point which is used as indication of light oil and intermediate fraction of fuel oil A
Best suited for management of plant and product control
Explosion-proof TIIS d2G4 certified
Meas. range
-30 - +20 degrees C
|
Cold Filter Plugging Point Analyzer
|
|
|
DKK-TOA CGP-31
|
|
Enables measurement of CO2 in both liquid phase and gas phase
Wide measurement range(0.1 - 100%)
Membrane electrode allows for reliable measurement
Power-saving design; rechargeable battery adaptable
Waterproof design(IP67: 1m depth, up to 30mins)
Meas. range
Liquid phase: 1.49 - 1490 mg/L Gas phase: 0.1 - 100%
|
Portable Carbon Dioxide Meter
|
|
|
DKK-TOA CGS-12
|
|
Calibration Gas Generator CGS-12
Calibrator for SO2/NOX/CO analyzers
Built-in zero gas generator enables suction of ambient air & purification into zero gas
Concentration of span gas (calibration) is freely adjustable between 1:100 & 1:10000 of component gas concentration
|
Calibration Gas Standards Generator
|
|