DKK-TOA CM-30R
|
|
JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement
Built-in pure water temperature compensation
USB (Host) and LAN equipped as standard specification
Compliant with USP<645> requirements
Meas. range
0 - 200.0 S/m 0 - 20.00 MΩ・m Chloride 0 - 4.00% Concentration 0 - 200% 0 - 100.0 degrees C |
Conductivity Meter
|
|
|
DKK-TOA OC-711 / OC-950
|
|
Immersion/Drop-In Type DO Holder OC-711 / OC-950
Lightweight PVC holder; length of immersion type holder: 0.3 - 3.5 m, length of stainless steel protection pipe for drop-in type holder: 2 - 6 m
Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)
|
Immersion/Drop-in Type DO Holder/Detector with Water Jet Cleaner
|
|
|
DKK-TOA MM-60R
|
|
2-Channel model with automatic sensor identification ● Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel ● 0.01/0.001 pH display switchable ● Large color graphic LCD display ● JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement ● USB (Host) and LAN equipped as standard specification ● External printer connectable ● Multiple samples measurement (turntable connection)... |
Multi-Function Water Quality Meter
|
|
|
DKK-TOA PPA
|
|
Designed for oil refinery
Continuous measurement of pour point which is used as indication of light oil and intermediate fraction of fuel oil A
Best suited for management of plant and product control
Explosion-proof TIIS d2G4 certified
Meas. range
-30 - +20 degrees C
|
Pour Point Analyzer
|
|
|
DKK-TOA GFS-312E
|
|
Sulfur Dioxide Analyzer GFS-312E
US EPA Approval
Continuous measurement of SO2 by using Ultraviolet fluorescence method
Improved optical system reduces the impact from interfering substances
Easy-to-use touch panel
Meas. range
0 - 0.05, 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Sulfur Dioxide Analyzer
|
|
|
DKK-TOA EMNA-10
|
|
Continuous measurement of Na+ ion concentration of boiler water at ppb level
Auto self-detection of degradation of ion-exchange system
Meas. range
0 - 0.1/1 - 100/10 - 1000 ppb (manual swtiching)
|
Sodium Ion Monitor
|
|
|
DKK- TOA CLF-1610
|
|
Measures free residual chlorine of clean water continuously with the reagentless polarographic method
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 1/2, 0 - 1/3, 0 - 2/3 mg/L (ppm) (2-range)
|
Reagentless Free Chlorine Analyzer
|
|
|
DKK-TOA IM-32P
|
|
2-channel type, simultaneous measurement and display of pH/ions
Power-saving design; rechargeable battery adaptable
Waterproof design (IP67: 1m depth, up to 30mins)
Data storage up to 1000 points
PC and external printer connectable
Measurement items
pH, ORP, ions, temperature (ORP and ion electrodes sold separately) |
Handheld Ion/pH Meter
|
|
|
DKK-TOA ODM-100A (2-wire) / ODM-110A (4-wire)
|
|
Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire)
Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case
Simplified calibration procedure; auto detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA AA-1(for Standard) / AA-2 (for Ultrapure Water)
|
|
Single-function (no indication) conductivity analyzer for field installation
Easy installation for the one-unit amplifier and detector
Output: 4 - 20mADC
Power supply: 100VAC
Meas. range
AA-1: 0 - 2 μS/cm to 0 - 10000 μS/cm AA-2: 0 - 0.2/0.5/1.0 μS/cm
|
Conductivity Detectors with Amplifier
|
|
|
DKK-TOA ME-6/7/11T series (high sensitivity type)
|
|
Toroidal type teflon detector with excellent corrosion/heat/pressure resistance
Accurate results for high conductivity corrosive solutions (such as strong acid/alkali)
Types of detectors available: flow-through, immersion, pipeline insertion, etc.
Meas. range
Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm
|
Electromagnetic Conductivity Detector
|
|
|
DKK-TOA GSS‐304B(KCl Replenish-Free) / GSS‐314B(KCl Refillable)
|
|
Easy-to-replace electrode tip and reference electrode junction tip
Alkali-resistant glass tips and hydrofluoric-acid-resistant glass tips available
KCl non-refillable type for wastewater treatment; KCl refillable type for processes
Selection of electrode holder: immersion type, drop-in type and flow-through type
Meas. range
pH: 0 - 14
|
Exchangeable Tip pH Electrode
|
|
|
DKK-TOA COD-203A
|
|
Automated COD Analyzer COD-203A
Measures COD of river water, lake water and effluent in accordance with JIS K 0806 instruction "Automatic chemical oxygen demand meter"
Acid process and alkaline process available
Capability of two flow paths measurement
Meas. range
0 - 20 mg/L to 0 - 2000 mg/L
|
Automatic COD Analyzer
|
|
|
DKK-TOA A5/A6 Series
|
|
Hermetically sealed 2-electrode type detector featured with excellent heat-proofing and pressure tightness
Pipeline-insertion/immersion/flow-through/throw-in/leadless, etc. type available
Four types of cell constants available: 0.01, 0.1, 1.0, 10 cm-1
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Industrial Conductivity Detector
|
|
|
DKK-TOA CFPP
|
|
Designed for oil refinery
Continuous measurement of plugging pour point which is used as indication of light oil and intermediate fraction of fuel oil A
Best suited for management of plant and product control
Explosion-proof TIIS d2G4 certified
Meas. range
-30 - +20 degrees C
|
Cold Filter Plugging Point Analyzer
|
|
|
DKK-TOA GUX-313E
|
|
Ozone Analyzer GUX-313E
US EPA Approval
Continuous measurement of O3 concentration by using UV photometry method
Easy-to-use touch panel
Meas. range
0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Ozone Analyzer
|
|
|
DKK-TOA SOD-35D (2-Wire Transmitter) SOC-71 (Sensor)
|
|
Polarograph type DO analyzer with intrinsically safe explosion-proof function (combined with a Zener Barrier)
Alterable output range
Types of detectors available: immersion, flow-through and fermentation-used (electrodes: ELD-017/ELD-019)
Meas. range
Minimum : 0 - 1 mg/L Maximum: 0 - 20 mg/L
|
Intrinsically Safe Explosion-Proof Type DO Transmitter
|
|
|
DKK-TOA AUT-701
|
|
Dual system allows for 2-channel simultaneous titration
Strong&Float high performance electrodes
USB(Host) and LAN equipped as standard specification
Validation supporting function
Turntable, auto-sampling system and etc. connectable
|
Automatic Titrator
|
|
|
DKK-TOA OPM-1610
|
|
The monitor measures organic pollutant concentration of sample by detecting the absorbance of ultra violet ray(254nm)
Stable measurement realized with the UV absorptiomatric method
With energy-saving lamp it reduces electricity cost significantly
Meas. range
Absorbance: 0 - 2.5 Abs |
Organic Pollution Monitor (UV Instrument)
|
|
|
DKK-TOA HC-7 Series
|
|
Ideal for pH/ORP measurements in tanks and open water applications
Assemble electrodes available: 5600 (KCl refillable type); 5910 (KCl replenish-free type)
Mounting flanges for tanks available (50A, 100A, 150A)
|
Immersion Type pH/ORP Detector
|
|