HOB404 U12-013 TEMP/RH/ 2 X EXTERNAL ANALOG INPUT DATA LOGGER
|
|
>> Temperature, Humidity with 2 External Analog Inputs for Current or DC Voltage Measurement >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature); 0 to 95% RH (Humidity); 1 to 3000 lumens/ft2 (Light) Operating Ranges >> Stores up to 43,000 Measured Samples/Readings >> Sampling Rate of 1 Second to 18 Hours Adjustable by User >> 1 Year Replaceable Battery Life... |
Datalogger/Recorders
|
|
|
HOB903 CABLE-4-20MA 4-20MA INPUT CABLE
|
|
4-20mA Input Cable >> Cable for Connecting Sensor with 4-20mA Output to Logger >> Length: 18.5" >> Use in Outdoor and Indoor Environments |
Datalogger/Recorders
|
|
|
HOB904 CABLE-ADAP10 0-10V INPUT CABLE
|
|
0 to 10 Volts DC External Input Cable>> Input Range: 0 to 10 Volts DC >> Impedence: 20 KΩ with 0.6 mV Resolution >> Cable: 13mm (0.5") Tinned Braided Wire Leads >> Cable Length: 1.9 Meters (6.3 feet) >> Indoor Use Only
|
Datalogger/Recorders
|
|
|
HOB906 U-DT-1 U SHUTTLE DATA TRANSPORTER/DATA COLLECTOR
|
|
The pocket-sized Shuttle provides a convenient way to readout and relaunch many of the HOBO data loggers and bring the data back to your host PC. The HOBO Shuttle works with the HOBO U-series loggers and HOBO Weather Stations and Micro Weather Stations.
Features
4 MB non-volatile memory, allowing you to readout many loggers (504 loggers with 8K memory - some Pendant Loggers) (63 loggers with 64K memory - most U-Series Loggers) (7 loggers with 512K memory - weather/micro stations and... |
Datalogger/Recorders
|
|
|
HOB402 U12-012 TEMP/RH/LIGHT/1 X EXTERNAL ANALOG DATA LOGGER (LOGGER ONLY)
|
|
The HOBO U12 Temp/RH/Light/External is a four-channel data logger that provides temperature, relative humidity, relative indoor light level measurements and accepts one external input.
>> Temperature, Humidity, Light with 1 External Analog Input for Current or DC Voltage Measurement >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature); 0 to 95% RH (Humidity); 1 to 3000 lumens/ft2... |
Datalogger/Recorders
|
|
|
HOB901/HOB902 SOFTWARE KIT FOR WINDOWS/MAC (INCLUDES SOFTWARE AND CABLE)
|
|
This totally new HOBOware for Windows supports all HOBO U-Series loggers, including HOBO Water Level and HOBO Pendant loggers; Onset's HOBO Weather Station and HOBO Micro Station; and incorporates valuable new capabilities such as scaling data to sensor units and saving graphs so they can be recalled and used in the future. In addition, HOBOware Pro includes Post-Processing Assistants, for Growing Degree Days and Grains per Pound. The USB Interface cable is included with the HOBOware... |
Datalogger/Recorders
|
|
|
HOB301-UX120-017 4-CHANNEL PULSE, EVENT, STATE AND RUN-TIME DATA LOGGER (LOGGER ONLY)
|
|
The HOBO UX120 Pulse Logger is a highly versatile, 4-channelenergydata logger that combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals – from energy auditors to building commissioners – to easily track building energy consumption, equipment runtimes, and water and gas flow rates. The HOBO UX120 Pulse Logger is available in astandard memory model (UX120-017)capable of 500,000 measurements and anexpanded memory version... |
Datalogger/Recorders
|
|
|
HAC001-RADALERT 100V2 RADIATION MSV/HR MREM/HR METER(HANDHELD NUCLEAR RADIATION MONITOR) - FROM USA
|
|
The Radalert HAC001 is a general purpose geiger counter that measures alpha, beta, gamma, and X-radiation. Exciting new features of the Radalert 100™ (which is the upgraded version of the popular Radalert 50™), include a three-second update and a utility menu that allows you to change the default settings for several operating parameters. Its digital liquid crystal display (LCD) shows the current radiation level in your choice of milliroentgens per hour from .001 to 110 or counts per minute... |
Nuclear Radiation Monitor
|
|
|
HAC001E-CRM-100V2 BASIC RADIATION MSV/HR MREM/HR METER(HANDHELD NUCLEAR RADIATION METER) - FROM USA
|
|
*Without Auto Alert Function.The CRM-100™ is a general purpose geiger counter that measures alpha, beta, gamma, and x-radiation. It is intended for personal safety and educational purposes. Like the popular Radalert 100™, the CRM-100™ features a 3-second update on its digital liquid crystal display (LCD). The LCD shows the current radiation level in your choice of milliroentgens per hour from .001 to 110 or counts per minute (cpm) from 0 to 350,000. When SI units are selected, the LCD... |
Nuclear Radiation Monitor
|
|
|
HAC001S1 USB PC SOFTWARE GEIGER GRAPH FOR RADLERT/CRM/INSPECTOR GEIGER COUNTER - FROM USA
|
|
You can configure the program so that a Radiation Alert executes a computer program or batch file, and/or sets voltage to another serial port on the computer to trigger a relay switch that stops a machine, for instance.
Pleasing interface, including and easy to understand running total and summary of Radiation Count data, attractive 3D graphing, a flashing LED with each radiation count, and handy speed buttons.
Identify your monitoring station and... |
Nuclear Radiation Monitor
|
|
|
HAC002-INSPECTOR(VERSION 2) ALERT RADIATION MONITOR WITH XL SENSOR AREA(FROM USA)
|
|
Product Description
Quickly alerts the user to the presence of harmful levels of nuclear radiation
Improves safety in the laboratory and in the field
Automatically compensates for GM tube dead time
Will not jam in high radiation fields
CE Certified, RoHS Compliant & Meets WEEE standards
|
Nuclear Radiation Monitor
|
|
|
HAC002B-Ionizing Radiation Detector with External Detector(Geiger Counter)-Alpha, Gamma,Beta Rays Counter
|
|
Four-digit, LCD display
External probe detects low levels of alpha and beta particles, gamma and x-rays for a range of ionizing radiation type detection
Red count light and beeper indicate each ionizing radiation change event
Comes with a carrying case that provides open access to the display window and operation panel, and has a probe cover that protects the detector, and allows for one-handed operation
1 year limited warranty |
Nuclear Radiation Monitor
|
|
|
HAC001B-HAND HELD MONITOR 200 FOR ALPHA, GAMMA, BETA, X-RAYS - FROM USA
|
|
SE INTERNATIONAL HAND HELD MONITOR 200 FOR ALPHA, GAMMA, BETA, X-RAYS NEW
The Monitor 200 measures alpha, beta, gamma, and x-rays. Its digital display shows readings in your choice of CPM, CPS, μSv/hr, mR/hr, or in accumulated counts. It has a digital display, a red count light, and a beeper that sounds with each count detected. Other features include an adjustable timer, and selectable alert. With the free Observer USB Software Family, you can set computer alarms, and download your... |
Nuclear Radiation Monitor
|
|
|
HOB510C-M002V2 RAIN GAUGE SMART SENSOR (0.2MM) WITH 2M CABLE COMPLETE W USB SOFTWARE AND LOGGER
|
|
This Rain Gauge Smart Sensor measures rainfall with intensity up to 12.7 cm per hour with a resolution of 20 mm, and 1% accuracy for rainfall rates up to 0.2 mm/hour. The tipping bucket mechanism is mounted on a stainless steel shaft with brass bearings. This model includes a 2m cable.
Environment:The S-RGB-M002 Sensor is for use in Outdoor environments
Measurements:The S-RGB-M002 Sensor supports the following measurements:
Rainfall |
Rain gauge
|
|
|
HIO0006-3286-20 POWER CLAMP METER
|
|
Functionality and Safety Packed into a Handheld Unit
Use as a single-phase power meter
Measure phase on a single-phase line
Simple checking of three-phase lines
Check power supply fluctuations
For harmonic suppression
External output of data to PC
Printer output to 9442 (optional)
|
Power clamps
|
|
|
HiTemp140-PT-TSK Data Logger
|
|
The HiTemp140-PT-TSK is a kit that includes a HiTemp140-PT data logger housed in a thermal shield. The combined features of the data loggers +/-0.1°C accuracy and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. The built in 24” RTD probe can be bent or spiraled in any direction, making it easy to log temperatures in hard to reach places. This rugged data logger system can be placed in and withstand temperatures from... |
Data Logger Systems
|
|
|
HiTemp140-TSK Data Logger
|
|
The HiTemp140-TSK is a kit that includes a HiTemp140 data logger housed in a thermal shield. The combined features of the ±0.1°C accuracy of the HiTemp140 and the properties of the durable thermal shield allow the device to be used for a wide range of validation applications. This rugged system can be placed in and withstand temperatures from -200°C to 250°C, making it ideal for use in autoclave validation, monitoring food processing and dishwasher testing.
Using the MadgeTech software,... |
Data Logger Systems
|
|
|
HiTemp150-PT-TSK Data Logger
|
|
The HiTemp150-PT-TSK is a kit that includes a HiTemp150-PT temperature data logger enclosed in a thermal shield. This durable system can withstand temperatures up to 250°C. The thermal shield can be easily removed from the HiTemp150-PT, so it may be used as a standalone data logger also.
Installing the data logger back into the thermal shield is simple, just open the enclosure, thread the probe through the end cap and fasten the thermal barrier together. The HiTemp150-PT-TSK is submersible... |
Data Logger Systems
|
|
|
HiTemp150-TSK Data Logger
|
|
The HiTemp150-TSK is a kit that includes a HiTemp150 data logger and thermal shield. This durable system can withstand temperatures up to 250°C (482°F). The device is easy to use, simply activate the logger, open the enclosure, insert the HiTemp150, thread the probe through the end cap and latch it back onto the barrier body. The system is then ready to use. The HiTemp150-TSK is built for applications that require extreme temperature monitoring, such as peanut roasting and food processing. |
Data Logger Systems
|
|
|
HiTemp150FP-TSK Data Logger
|
|
The HiTemp150FP-TSK is a temperature data logging system that includes a HiTemp150FP temperature data logger and thermal shield. This durable system can withstand temperatures up to 250°C (482°F).
The device is easy to use, simply activate the data logger and place in the monitoring area. This device’s high memory capacity allows it to measure and record data and hold up to 32,767 readings. When monitoring is complete, data can be downloaded to a computer for analysis and record... |
Data Logger Systems
|
|