CAX0135-CHAUVIN ARNOUX PEL113 (REPLACE OLD PEL103) POWER AND ENERGY LOGGER - CONTRACTORS KIT

SKU: CHAUPEL113PROKIT
  • PEL113 power and energy logger with current sensors, leads and Dataview software
  • Measure and records all data for energy consumption diagnostics
  • Hard carry case for equipment protection

 

Chauvin Arnoux PEL113 Power and Energy Logger - Contractors Kit

The Chauvin Arnoux PEL113 Power Energy Logger - Contractors Kit is the ideal kit needed for successful energy monitoring. Included within the kit is of course the PEL 113 Power Energy Logger and also current sensors, leads and software that are needed for data logging purposes. To keep the tester and equipment safe, the Contractors Kit comes with a rugged hard carry case that protects all components in transit and storage. Access to Chauvin Arnoux's technical supports, videos and guides are all included to help the end user. 4 x Reeling Boxes 3m Voltage Leads are also supplied that have a magnetic back allowing for magnetising to a distribution board. The PEL 113 also allows for data logging and data transfer thanks to the Wi-Fi connectivity.

Chauvin Arnoux PEL113 Power Energy Logger

The PEL 113 is perfect for both commercial and industrial installations helping businesses identify potential energy savings by finding power quality problems such as harmonics or poor power factor. Users are able to Remote monitor sites with data being viewed in real time at an installation.

The PEL113 measures and records all the relevant data for energy consumption diagnostics, recording continuously with intervals of 200ms between each measurement. Capable of 5 readings per second and recorded simultaneously on each phase, all data is captured as per the IEEE 1459 standard. Thanks to its large measurement ranges, voltage up 1,000 VAC/VDC and current up to 10 kVAC / 5 kVDC, the PEL 113 can log power values up to 10 GW/GVar/GVA, and energy up to 4 EWh/EVAh/EVarh. This makes the 104 ideal for energy usage analyses, load studies, energy surveys and complying with the energy audit requirements of ISO 50001 and EN 16247-3.

The PEL113 Power Energy Logger performs the following measurements:

  • RMS and DC measurements with 128 samples/cycle – simultaneously on each phase
  • AC and/or DC voltages up to 1000 V
  • Current up to 10 kA AC or 5 kA DC (depending on the current sensor)
  • Energy values up to 4 EWh / 4 EVAh / 4 EVarh & total energy (4 quadrants)
  • Phase data: cos φ, tan Φ, power factor (PF)
  • Crest factor
  • Harmonics up to the 50th order for currents and voltages
  • DC, 50 Hz, 60 Hz and 400 Hz measurements

Chauvin Arnoux and the PEL113 are dedicated to improving energy efficiency within sustainable, economical buildings. Indeed optimisation of energy consumption is in fact vital to fulfil the latest regulatory requirements. 

If when using the PEL 113 there isn't access to a normal pin adapter, the mains power adapter included in the kit, allows for the PEL to be powered through the voltage connections allowing for when measuring the circuit the circuit that is on the test can power the PEL113 during logging sessions. Data view software allows for professional PDF reports to be produced for customers and colleagues.

 

Key Features

  • Suitable for all types of electrical networks
  • Provides real-time oversight
  • Automatically recognises connected sensors
  • 4 voltage inputs and 3 current inputs
  • Operates without having to cut off mains power supply
  • Measures/records all energy consumption diagnostics data
  • Interval of 200ms between each measurement
  • 5 readings per second recorded simultaneously on each phase
  • Voltage range up 1,000 VAC/VDC
  • Current range up to 10 kVAC / 5 kVDC
  • Log power values up to 10 GW/GVar/GVA
  • Log energy up to 4 EWh/EVAh/EVarh
  • RMS and DC measurements with 128 samples/cycle – simultaneously on each phase
  • AC and/or DC voltages up to 1000 V
  • Phase data functions: cos φ, tan Φ, power factor (PF)
  • THD calculation for currents and voltages
  • Harmonics up to the 50th order for currents and voltages
  • DC, 50 Hz, 60 Hz and 400 Hz measurements
  • Suitable for workshop, factory, agency or building environments
  • Recordings are all time & date stamped
  • Built-in customisable Alarm mode
  • Large SD card ideal for lengthy measurement campaigns.
  • Communication modes; WiFi, LAN (Ethernet), Bluetooth, USB ports
  • Monitor measurements & recover data from anywhere in the world
  • Insert a SIM card for remote connection via a GSM 3G link
  • IRD server emails user should an alarm be triggered
  • Use the IRD server to view measurements remotely via the internet
  • Compatible with FREE multilingual Android App
  • Communicate via Bluetooth with the device through smart device
  • Built-in software sensor enables measurements for applications on motors
  • Motor measurements; rotation speed, torque & engine efficiency
  • Wi-Fi interface for PC access
  • PEL Transfer software analyses data and calculates cost of power consumed Software results displayed in selected currency
  • DataView processing software creates certified or customised reports
  • Self-powered via its voltage inputs up to 600 V
  • Backlit LCD screen with triple digital display
  • Compact magnetised casing, extremely portable
  • No impact on electrical cabinets
  • Data recorded as per the IEEE 1459 standard
  • Rated IP54, 1000V CAT III and 600V CAT IV

The PEL 112 vs PEL 113 vs PEL 115

  PEL112 PEL113 PEL115
Display None Quadruple digital display
Types of installations Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations
Number of channels 3 voltage inputs, 3 current inputs (neutral current calculated) 4 voltage inputs, 4 current inputs
Network frequencies DC, 50Hz, 60Hz and 400Hz
Voltage (measurement ranges) 10.00 - 1,000Vac / 100.00 - 1,000Vdc
Current 5 mAac to 10 kAac / 50 mAdc to 5 kAdc
Ratio Up to 650,000V / up to 25,000A
Power (P, Pf, P+, Punb, Qf, N, D, S) 10W to 10GW / 10var to 10Gvar / 10VA to 10GVA
Energy Up to 4 EWh / 4 EVAh / 4 Evarh (E = 10^18)
Phase cos φ, tan Φ, PF
Harmonics THD
Phase order Yes
Min/Max Yes
Alarm Yes
Mounting Magnet Hook (optional)
Acquisition rate / Aggregation period 5 measurements/s - 1 min to 60 min
Data storage SD card, 8GB (up to 32GB on SD-HC card)
Communication USB, Ethernet, Wifi (Access point and Hotspot), IRD Server DataView® Synch
Power supply 110V - 250V (+10 %, -15 %) at 50-60Hz & 400Hz Powered by the phase – 1,000V AC/DC
Safety IEC 61010 600V CAT IV and 1000V CAT III IEC 61010 1000 V CAT IV
Dimensions 256 x 125 x 37mm without sensor 245 x 270 x 180mm without sensor
Weight 900g 950g <3400g
Casing IP54 IP67
Operating temperatures -20°C to +50°C 0°C to +50°C -20°C to +50°C

What's In The Box?

  • Chauvin Arnoux PEL113 Power Energy Logger
  • 3 x MA194 Flexible Current Sensors
  • Chauvin Arnoux Dataview Reporting Software
  • Self-Powering Adaptor (P01102204B)
  • Hard Carry Case with Custom Foam Inserts
  • 4 x Reeling Boxes 3m Voltage Leads
  • 4 x Magnetised Voltage Probes
  • 4 x Crocodile clips
  • Set of Coloured Rings/Inserts
  • USB Cable
  • USB SD Card Adaptor
  • User Manual & Quick Start Guide
  • Declaration of Conformity
 

 

 