DKK-TOA HC-8Series
|
|
Designed for pH/ORP measurements in closed loop lines and environments where process pressure exists, such as pipes or sealed tanks and etc.
Assemble electrodes available: 5610(KCl refillable type); 5910(KCl replenish-free type)
|
Flow-Through Type pH/ORP Detector
|
|
|
Kyoritsu 8035
|
|
New technology permits safe testing, without the need of direct contact between probes and live wires.
•
The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm.
•
Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.
•
The instrument can be fixed to a metal panel via the magnet on the back side.
•
Wide measuring range for 3 phase installations from 70V to 1000V AC.
•
Super brightness function... |
Phase Indicator
|
|
|
Lutron Conductivity Meter - PCD-431
|
|
FEATURES * 2 ranges : 2,000 uS, 20 mS. * Temperature measurement, ℃/℉ * Automatic temperature compensation. * Probe with the meter, all in one. * Carbon rode electrode, high reliability. * Data hold, Record ( max., min. ). * IP-67 Water resistance, heavy duty. * External calibration buttons. * DC 1.5V battery ( UM-4, AAA ) x 4. |
Conductivity Series
|
|
|
Sew 186 CB
|
|
FEATURES
Cable Tracer
● Trace wires or cables.● Volume control.● Tip & Ring identification.● 2 bi-colored LEDs ( Line 1 & Line 2).● Tone speed selection : Fast & Slow.● A phone jack is designed for headset or handset. (Amplifier probe) Digital Multimeter
● 4000 counts.● ACV, DCV.● Ohm, Diode, & Continuity testing.● Auto-range.● Data hold.● Low battery indication.● Select function.● Auto-off.
... |
Cable Tracer and Digital Multimeter
|
|
|
Chauvin Arnoux PEL 103 Power Logger
|
|
Power & Energy Logger
Control your consumption, manage your energy spending and monitor your network
With their ergonomic design suitable for all types of cabinets, the PEL loggers provide all your power and energy measurements simultaneously.
|
Power Quality Analysers
|
|
|
Kyoritsu 4102A
|
|
The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
•
Dust and drip proof. (designed to IEC 529 IP54)
•
Earth resistance value can be read directly from the scale.
•
Designed to meet IEC 61010-1 safety standard.
•
Capable of measuring earth voltage.
•
Small and lightweight. Shock resistant new case material.
•
2mA measuring current... |
Earth Testers
|
|
|
Kyoritsu 8141
|
|
Applicable model
5000/5001, 5010/5020, 6310
* Cannot be used for power measurement.
|
Leakage current clamp sensors
|
|
|
Sew 6213A IN-M
|
|
FEATURES
● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Delectric Absorbtion Ration (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.●... |
H.V. Insulation Testers (OLED Display 1kV up)
|
|
|
Kyoritsu 2412
|
|
Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
•
Frequency filter switch to eliminate the effect of harmonics.
•
Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.
|
Leakage Clamp Meters
|
|
|
Tenmars TM-91 Radiation Monitor
|
|
Model No.: : TM-91
Product Description
- Display units in uSv/h, uRem/h and mRem/h. - Built-in a GM tube. - Quick response to the radiation strength of Beta(B), Gamma(y) and X-ray. - Auto Ranging. - Automatic detection, easy setting. - A beeper chirps with each radiation count. - Audio alarm setting function. |
Radiation Monitor
|
|
|
DKK-TOA ICA-2000 Series
|
|
Compact main unit holding up to 3 pumps and 2 detector units
Simple system expansion by optional combined pump-detector unit installation
Remote data monitoring capability due to LAN based main unit/PC control signal connection
PC linked pos+/neg- ion 2-channel real-time chromatograph data display and report printout
Non-metal pump for post column reactor is available
Meet a wide range of water supply measurement needs such as cyanide/bromate, chlorate, etc.
High sensitivity analysis... |
Ion Chromatograph
|
|
|
DKK-TOA DO-31P
|
|
DO electrodes for incubator bottles and stirring-free DO electrodes available
Power-saving design; rechargeable battery adaptable
Waterproof design (IP67: 1m depth, up to 30mins)
Data storage up to 1000 points
Meas. range
0 - 20.00 mg/L (0 - 50.0 mg/L)* 0 - 200% (0 - 500%)* *When the high-concentration membrane is used (optional) 0 - 50℃ |
Handheld DO Meter
|
|
|
Lutron Oxygen Meter - DO-5510HA
|
|
FEATURES * The polarographic type oxygen probe with an incorpo- rated Temp. sensor, high precision measurement for Dissolved Oxygen(DO), Oxygen in air(O2) & Temp. measurement. * Heavy duty dissolved oxygen probe, probe head can connect with BOD bottle. * Automatic Temp. compensation from 0 to 50 ℃ for sensor probe. * Build in " % SALT " & " Mountain Height " compensation adjustment button. * Microprocessor circuit. * Records Maximum, Minimum value. |
Dissolved Oxygen Series
|
|
|
Anemometer-Wind Speed sensor for Data Logging
|
|
Wind speed sensor for use with the RFPulse2000A or Pulse101A data loggers. The anemometer can be purchased stand alone or with four different cable length options. The Wind101A is also available as an entire system including the Pulse101A Data Logger, Weather Proof Enclosure, 3-Cup Anemometer, and IFC200 Software and Interface Cable Package. |
Weather
|
|
|
Kyoritsu 8205AMultifunction and Safety Testers demo panel
|
|
This demonstrative panel is intended to demonstrate the use Multifunction testers and specific instruments like Continuity, Insulation, Earth, Loop and RCD testers of Kyoritsu. The panel simulates an electrical installation with TT and TN distribution systems, easy selectable by a switch on the panel. The tests that can be carried out are:
•
Continuity Test of Protective and Equipotential conductors
•
Insulation Resistance Test
•
Earth Resistance Test (Volt-Ampere... |
Demonstration Panels
|
|
|
FLIR i5 Infrared Camera
|
|
100 x 100px Infrared Camera
THE FLIR i5 IS THE MOST COMPACT, LIGHTWEIGHT AND EASY-TO-USE INFRARED CAMERA OF ITS CLASS CURRENTLY AVAILABLE ON THE MARKET
Most FLIR products on this site are advertised at the list price. Please use the 'Best Quote' link on the right for our discounted price.
FLIR Part No: 39301-0103
|
i5 Infrared Camera
|
|
|
DKK-TOA DVP-03
|
|
Designed for oil refinery
Measures vapor pressure of petroleum products like gasoline
Vapor pressure is measured by measuring static pressure of the sample that is jetting out from the nozzle at the constant temperature
Measurement result attained via Reid method for vapor pressure
Meas. range
0.01 - 1 MPa abs 0 - 0.15 MPa abs
|
Vapor Pressure Analyzer
|
|
|
Sew ST-96 ST-72
|
|
Test Voltage : 2kV 50-60Hz ● AC Ampere Over Load Scale:200%, 300%, 500% ● Composition:Glass Window, ABS resin frame and case, Bakelite base ● Color:Black case and frame, white scale plate and meter body ● Pointer:Stick shape in black color ● Pointer Length:55mm. |
Switchboard Instrument
|
|
|
Fluke 80i-110s AC/DC Current Clamp
|
|
Current Range: 0.1 to 100A DC or 0.1 to 70A AC
Basic Accuracy (DC to 1kHz):
100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA
10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading
Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
Bandwidth: 1Hz to 20kHz
Working Voltage: 600V AC rms
Maximum Conductor Size: 1.8 mm (.46 inch) diameter
Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II,... |
Current Clamps
|
|
|
Testo 174-Series Data loggers
|
|
Displays current temperature reading
Displays current humidity reading (174H Only)
Large display
Fast data analysis and documentation on a PC
Waterproof according to IP65
Measurement data memory for 16,000 measurement values
|
Data loggers
|
|