DKK-TOA HM-25R
|
|
Cost-effective basic model
Easy-to-read large customized LCD display
High-performance with the Strong&Float (internal solution concentration checker) pH electrode
External printer connectable
Data storage up to 300 points
Meas. range
pH 0.00 - 14.00 ORP 0 - ±2000.0 mV (ORP electrodes sold separately) 0 - 100.0 degrees C |
pH meters
|
|
|
DKK-TOA HM-20J
|
|
Easy-to-read LCD display
AC/DC 2-way power supply
ORP measurable
mV shift function
Cost-effective designed in a compact size
Meas. range
pH 0.00 - 14.00 ORP 0 - ±1999 mV (electrode sold separately) |
pH meters
|
|
|
DKK-TOA HDM-137A(2-wire)/HDM-138A(4-wire)
|
|
Industrial ORP Transmitter HDM-137A(2-wire)/HDM-138A(4-wire)
Easy-to-use ORP analyzer for field installation in a compact and rigid aluminum enclosure
Automatic check done with standard solution
Auto-detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HDM-135A(2-wire)/HDM-136A(4-wire)
|
|
Industrial pH Transmitter HDM-135A(2-wire)/HDM-136A(4-wire)
Easy-to-use pH analyzer for field installation in a compact and rigid aluminum enclosure
Easier calibration done with standard solution
Auto determination of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-1 - 14
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G95 (KCl Replenish-Free)
|
|
Drop-In Type Detector for Replaceable Tip Electrode HC-G95 (KCl Replenish-Free)
Two selections: throw-in type for deep tanks or drop-in type with a protection pipe
Made from transparent PVC (heat resistance: 60 degrees C)
SUS protection pipe (maximum length: 5 m) and mounting bracket available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
|
|
Flow-Through Type Holder for Replaceable Tip Electrodes HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
HC-G80: Transparent holders made of PVC (heat resistance: 60 degrees C) ; maximum pressure resistance: 0.15MPa
HC-G82: PP/SUS316 part (heat resistance: 80 degrees C) and PVDF/SUS316 part (heat resistance: 100 degrees C) ; maximum pressure resistance: 0.3 MPa
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
|
|
Immersion Type Holder for Replaceable Tip Electrode HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
HC-G70: Transparent PVC holder (heat resistance: 60 degrees C) and semi-transparent PP holder (heat resistance: 80 degrees C) available
HC-G72: SUS316 holder (heat resistance: 80 degrees C)
Length: 0.5 - 3.0m
KCl refillable type stores KCl inside the holder
Mounting bracket/flange available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-8Series
|
|
Designed for pH/ORP measurements in closed loop lines and environments where process pressure exists, such as pipes or sealed tanks and etc.
Assemble electrodes available: 5610(KCl refillable type); 5910(KCl replenish-free type)
|
Flow-Through Type pH/ORP Detector
|
|
|
DKK-TOA HC-7 Series
|
|
Ideal for pH/ORP measurements in tanks and open water applications
Assemble electrodes available: 5600 (KCl refillable type); 5910 (KCl replenish-free type)
Mounting flanges for tanks available (50A, 100A, 150A)
|
Immersion Type pH/ORP Detector
|
|
|
DKK-TOA HC-64
|
|
Ideal for pure water measurements like boiler water (low electric conductivity)
Low flow injection of sampling allows for accurate measurement
Assemble electrodes available: MG-511-2F (glass electrode) 4164-2F (reference electrode) 6149-2F (temperature compensation electrode)
|
pH Sensor for Pure Water Measurement
|
|
|
DKK-TOA HBM-165H(2-wire)
|
|
pH / ORP Transmitter with HART Interface HBM-165H(2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Available for both pH and ORP measurements
Diecast aluminum enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
-1.00 - 15.00 ORP -2000 - 2000 mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-160/HBM-162(4-wire)
|
|
Industrial pH/ORP Transmitter HBM-160/HBM-162(4-wire)
Multi-function pH/ORP analyzer for field installation in a compact aluminum diecast enclosure
One-touch calibration and various self-diagnostic functions
2-point contact signal and 2-channel output including temperature (RS-232 optional)
Power supply: AC90~264V, 50/60Hz
Meas. range
pH meter (HBM-160) : pH -1 - 15 ORP meter (HBM-162) : ORP -2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-100A / HBM-102A
|
|
Compact DIN 96 size design
Auto-detection of electrode deterioration
Automated self-diagnosis of fault (burn-out output)
Alterable alarm contact signal (4-point)
2-channel output (RS-232 optional)
Meas. range:
HBM-100A: pH; -1 - 15 HBM-102A: ORP; -2000 - +2000 mV |
Panel Mount pH/ORP Analyaer
|
|
|
DKK-TOA GUX-313E
|
|
Ozone Analyzer GUX-313E
US EPA Approval
Continuous measurement of O3 concentration by using UV photometry method
Easy-to-use touch panel
Meas. range
0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Ozone Analyzer
|
|
|
DKK-TOA GSS‐304B(KCl Replenish-Free) / GSS‐314B(KCl Refillable)
|
|
Easy-to-replace electrode tip and reference electrode junction tip
Alkali-resistant glass tips and hydrofluoric-acid-resistant glass tips available
KCl non-refillable type for wastewater treatment; KCl refillable type for processes
Selection of electrode holder: immersion type, drop-in type and flow-through type
Meas. range
pH: 0 - 14
|
Exchangeable Tip pH Electrode
|
|
|
DKK-TOA GNC-224-1
|
|
Flue Gas Hydrogen Chloride Analyzer GNC-224-1
Continuous measurement of flue gas hydrogen chloride concentration produced in incineration plants by ion electrode method
Small size chloride ion electrode and auto-cleaning function equipped
Easy installation and maintenance attained with front panel operation
Meas. Range
0 - (50 - 2000) ppm 0 - (10 - 50) ppm (optional)
|
Flue Gas Hydrogen Chloride Analyzer
|
|
|
DKK-TOA GLN-314E
|
|
Nitrogen Oxides Analyzer GLN-314E
US EPA Approval
Chemical luminescence method
Alternating measurement of nitric monoxide (NO) and nitrogen oxides (NOx) ensures stable and continuous measurement of minute amounts of nitrogen oxides in the air
Easy-to-use touch panel
Meas. range
0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0, 0 - 2.0 ppm
|
Nitrogen Oxides Analyzer
|
|
|
DKK-TOA GFS-312E
|
|
Sulfur Dioxide Analyzer GFS-312E
US EPA Approval
Continuous measurement of SO2 by using Ultraviolet fluorescence method
Improved optical system reduces the impact from interfering substances
Easy-to-use touch panel
Meas. range
0 - 0.05, 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm
|
Sulfur Dioxide Analyzer
|
|
|
DKK-TOA GFC-311E
|
|
Carbon Monoxide Analyzer GFC-311E
US EPA Approval
Gas filter correlation method (IR method)
High sensitivity measurement enabled with multi-reflection cell
Easy-to-use touch panel
Meas. range
0 - 5, 0 - 10, 0 - 20, 0 - 50, 0 - 100 ppm
|
Carbon Monoxide Analyzer
|
|
|
DKK-TOA GCO-200
|
|
Flue Gas CO/O2 Analyzer GCO-200
CO/O2 analyzer with an electric electrolysis CO sensor and a galvanic battery adapted O2 sensor
Ease of maintenance, cost reduction attainable with simple constructed unit
Meas. range
CO: 0 - 200 to 2000 ppm (setting available at 100 ppm intervals)(assignable) O2: 0 - 25%
|
Flue Gas CO/O2 Analyzer
|
|