DKK-TOA WQC-24
|
|
Simultaneous measurement of up to 11 items (pH, DO, conductivity, turbidity, temp., salinity, total dissolved solid, specific gravity of sea water, water depth, ORP, chlorophyll, Ions(F-, Cl-, NO3-, Ca2+, K+, NH4+) ● Continuous measurement at depth of 100m ● Diameter of standard sensor module is 45mm ● Up to 1 month data storage |
Multi-Parameter Water Quality Meter
|
|
|
DKK-TOA LHC-7D
|
|
Electrode Holder with Lift Up Type Jet Cleaner LHC-7D
A detector which can lift up from the sample water and remove fouling from the pH/ORP electrode effectively.
Automatic cleaning system that applies alternate streams of wash water and chemical solution (such as a 5% hydrochloric acid solution) to clean the pH/ORP detector.
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA SSD-1610(For Low Concentration)/SSD-1620(For Medium Concentration)
|
|
Compact and piston automated analyzer
Types of detectors available: immersion, drop-in and pipe insertion
Long-life optical model and high reliability
RS-485 interface equipped as standard specification; compatible with Modbus communication system
Meas. range
SSD-1610: 0 - 30/500/1000 mg/L SSD-1620: 0 - 5000/10000/20000 mg/L (3-range, manual switching)
|
Suspended Solids Concentration Analyzer
|
|
|
DKK-TOA HSCA-2000
|
|
Designed for oil refinery
Enables low-concentration measurement ranged 0 - 10 ppm
Adopts credible energy-dispersive X-ray spectroscopy method
Simple composition (no motor and burner)
Easy-to-use touch panel
Explosion-proof TIIS ExpdⅡBT4 certified
Meas. range
0 - 10 ppm 0 - 500 ppm
|
Process Sulfur Content Analyzer
|
|
|
DKK-TOA NHMS-4
|
|
Simple measurement with just an ion electrode
Enables continuous ammonium ion measurements in discharged industrial wastewater, river and water purification plants
Automatic cleaning and calibration function ensures stable measurement
Easy-to-use touch panel
Low-concentration calibration function available
Meas. range
0.05 - 5/0.1 - 10/1 - 100 mg/L
|
Ammonium Ion Monitor
|
|
|
DKK-TOA GCO-200
|
|
Flue Gas CO/O2 Analyzer GCO-200
CO/O2 analyzer with an electric electrolysis CO sensor and a galvanic battery adapted O2 sensor
Ease of maintenance, cost reduction attainable with simple constructed unit
Meas. range
CO: 0 - 200 to 2000 ppm (setting available at 100 ppm intervals)(assignable) O2: 0 - 25%
|
Flue Gas CO/O2 Analyzer
|
|
|
DKK-TOA MM-60R
|
|
2-Channel model with automatic sensor identification
Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel
0.01/0.001 pH display switchable
Large color graphic LCD display
JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement
USB (Host) and LAN equipped as standard specification
External printer connectable
Multiple sample measuring capability (turntable connection)
Data storage up to 300... |
Dissolved Oxygen Meter
|
|
|
DKK-TOA WQC-22A
|
|
Easy measurement of 6 items (pH, temp., DO, conductivity, turbidity, salinity)
Ideal for applications such as rivers, lakes, dams, etc.
Easy maintenance with cartridge electrode
Measurements at depth of 30m is achievable with specific electrodes
AC/DC 2-way power supply
|
Water Quality Checker
|
|
|
DKK-TOA MAC-355
|
|
pH Meter with Auto Calibration MAC-355
Automatic cleaning and 2-point calibration functions serve long-term reliable pH measurement with just little maintenance
Lift-up type design incorporated with air jet cleaning allows for superior cleaning effect and stable measurement
Self-diagnosis and useful message display
Meas. range
pH: -1 - 15
|
pH Meter with Auto-Calibration/Chemical Cleaner
|
|
|
DKK-TOA ALF-1600
|
|
Continuous measurement of alkalinity data in water purification process by coulometric titration method
Requires only 1/4 reagent volume of existing model
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 50/100 mg/L (ppm) (2-ranges)
|
Alkalinity Analyzer
|
|
|
DKK-TOA COL-330
|
|
Measures color of oil products and coloration out of mixed heavy oil from heat converters, etc.
Compact onboard spectroscope allows for a broad range of wavelength measurement
Saybolt color, ASTM color, APHA color measurable
Explosion-proof TIIS ExpdⅡBT4 certified
|
Process Colorimeter
|
|
|
DKK-TOA CRM-1600
|
|
Automated intermittent monitoring unit; Spectrometric Method using 1,5-Diphenylcarbazide
Stuck of the electromagnetic valve has been improved with rotating measurement cell
Designed for discharged wastewater of plating factory, river water quality and related fields
Meas. range
0 - 0.5/1.0 mg/L (2-ranges)
|
Hexavalent Chromium Monitor
|
|
|
DKK-TOA GNC-224-1
|
|
Flue Gas Hydrogen Chloride Analyzer GNC-224-1
Continuous measurement of flue gas hydrogen chloride concentration produced in incineration plants by ion electrode method
Small size chloride ion electrode and auto-cleaning function equipped
Easy installation and maintenance attained with front panel operation
Meas. Range
0 - (50 - 2000) ppm 0 - (10 - 50) ppm (optional)
|
Flue Gas Hydrogen Chloride Analyzer
|
|
|
DKK-TOA COD-60A
|
|
The integrated oxidation & titration design and the sequence control function simplified operations
Smaller waste solution (lower than 10mL per measurement)
Real time display of sequence and titration curve
Meas. range
0 - 20.0/40.0/100/200/400/1000 mg/L |
Simplified COD Meter
|
|
|
DKK-TOA TB-31
|
|
● Immersion type of sensor which is convenient for turbidity measurement in fields ● Reliability of low-concentration measurement has been improved (repeatability within the range of ±0.5NTU) ● Power-saving design; rechargeable battery adaptable ● Waterproof design (IP67: 1m depth, up to 30mins)
Meas. range
0.0 - 80.0 NTU (mg/L) 0 - 800 NTU (mg/L) Switch modes: auto/manual
|
Portable Turbidity Meter
|
|
|
DKK-TOA SHBM-161 / 163 (2-wire)
|
|
Compact diecast aluminum enclosure
ExiallCT4 (combined with a Zener Barrier) explosion-proof and IP65 conformed enclosure
Easy calibration done with standard solution
Auto-detection of electrodes deterioration
Alterable output range
Meas. range
SHBM-161: pH; -1 - 15 SHBM-163: ORP; -2000 - +2000 mV
|
Intrinsically Safe Explosion-Proof Type Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA FS-3
|
|
The cleaning process done by two filters alternately allows for continuous supply of sample
Filtration rate
1 - 6 L/min (Varies from sample turbidity) |
Sand Filter
|
|
|
DKK-TOA U-221
|
|
Alternative model to existing controller such as U-22, U-02, etc.
Same panel cut size, easy installation
Interactive input interface supports auto-calibration and multi-stream
Auto-calibration, self-diagnostic, remote control, communication function equipped
|
Controller
|
|
|
DKK-TOA ODL-1600
|
|
Oil film is detected by measuring differences of the amount of laser reflectance of oil and water
With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively
Contact-free and easy maintenance
Detectable range
0.3 - 3 m
|
Oil Film Detector
|
|
|
DKK-TOA AF-100
|
|
Enables bacteria and cell measurements in 50 sec.
Highly sensitive measurement at 1 - 1000 cells/mL level
Enables direct measurement of membrane filter
Compliant to sanitary management by swap test
Useful functions such as ATP concentration and cell converted value available
Automatic reagent dispenser is optional (DF-10 sold separately)
|
ATP Analyzer
|
|