• Filter
Created by: Administrator
Created on: 01 April 2020

FLI0021M DR FLU 410 (226B) MASS THERMAL FEVER SCREENING SYSTEM PDF Catalog:https://drive.google.com/open?id=1GG3p0J071D8aAJhmNra6JQY7E17YrvTT Video:https://www.youtube.com/playlist?list=PLhnPbpA7vbtfOti93vg3lkUgphyZiKrbp   REQUIRED SET: FLI0021M - Main unit FLI0021A02 - Tripod OPTIONAL:FLI0021A03C: Compatible PC with advisable ~23 inch monitorFLI0021T: Product training, Basic Calibration and Setup in your site office (cost depends on locations starting from RM1890)   Key Features Efficient & rapid body scanner Temperature range of 20˚C to 60 ˚C (68˚F - 140˚F) Little impact on an area's population traffic efficiency Audible voice alarm / visual red box indicator Self compensates for changes to ambient temperatures and distances Scan two faces simultaneously Non-contact measurement - ensuring safety of detection personnel Precise due to increased pixel count of 384 x 288 Built-in AI intelligence Polysilicon-FPA detector A single photo produces up to 110k temperature measuring points, including in hair Cost effective, safe and easy to maintain Quick to deploy including installation, commissioning and powering up. Supports continuous 24 hour monitoring...

Created by: Administrator
Created on: 14 December 2017

  The SERIES F Shape Stainless Steel Pitot Tube is constructed from corrosion resistant stainless steel with permanently etched insertion depth graduations for a lifetime of service. The static pressure port is parallel to the sensing tube to allow quick, easy alignment of the tube with air flow. A universal model fits the user supplied 3/4" schedule 40 pipe in any length.   Model Description DWY001-160-12 Stainless steel Pitot tube, 5/16" 8mm dia., 12-5/8" 35cm insertion length. DWY002-160-18 Stainless steel Pitot tube, 5/16" 8mm dia., 18-5/8" 50cm  insertion length. DWY003-160-24 Stainless steel Pitot tube, 5/16" 8mm dia., 24-5/8" 65cm insertion length. DWY004-160-36 Stainless steel Pitot tube, 5/16" 8mm dia., 36-5/8" 100cm insertion length. DWY005-160-48 Stainless steel Pitot tube, 5/16" 8mm dia., 48-5/8" 125cm insertion length. DWY006-160-60 Stainless steel Pitot tube, 5/16" 8mm dia., 60-5/8" 155cm insertion length. DWY007-160-8 Stainless steel Pitot tube, 5/16" 8mm dia., 8-5/8" 23cm insertion length. DWY008-160-KIT Kit containing 160-18, 160-24, 160-36, 160-48, and FREE carrying case ($150...

Created by: Administrator
Created on: 14 December 2017

  Straight Design, Accurate Positioning These Straight Stainless Steel Pitot Tube is constructed from corrosion resistant stainless steel with permanently etched insertion depth graduations for a lifetime of service. The static pressure port is parallel to the sensing tube to allow quick, easy alignment of the tube with air flow. The straight design allows for easy insertion into ducts through grills and pressure taps, as well as aids in positioning in hard to reach locations where a hook style Pitot tube may not allow access. Product Applications Monitor or control air velocity or air flow when combined with differential pressure gage, switch, or transmitter where hook style Pitot tubes don’t allow access Model Description DWY009-160F Straight stainless steel pitot tube, 18" 50cm DWY010-160F-24 Straight stainless steel pitot tube, 24" 65cm DWY011-160F-36 Straight stainless steel pitot tube, 36" 100cm DWY012-160F-48 Straight stainless steel pitot tube, 48" 125cm DWY013-160F-60 Straight stainless steel pitot tube, 60" 155cm DWY014-160F-KIT Kit containing 160F, 160F-24, 160F-36, 160F-48, and FREE carrying...

Created on: 21 January 2014

Flue Gas Hydrogen Chloride Analyzer GNC-224-1 Continuous measurement of flue gas hydrogen chloride concentration produced in incineration plants by ion electrode method Small size chloride ion electrode and auto-cleaning function equipped Easy installation and maintenance attained with front panel operation Meas. Range 0 -  (50 - 2000) ppm 0 -  (10 - 50) ppm (optional)

Created on: 21 January 2014

Flue Gas CO/O2 Analyzer GCO-200 CO/O2  analyzer with an electric electrolysis CO sensor and a galvanic battery adapted O2 sensor Ease of maintenance, cost reduction attainable with simple constructed unit Meas. range CO: 0 - 200 to 2000 ppm (setting available at 100 ppm intervals)(assignable)  O2: 0 - 25%

Created on: 21 January 2014

Calibration Gas Generator CGS-12   Calibrator for SO2/NOX/CO analyzers Built-in zero gas generator enables suction of ambient air & purification into zero gas Concentration of span gas (calibration) is freely adjustable between 1:100 & 1:10000 of component gas concentration  

Created on: 21 January 2014

Carbon Monoxide Analyzer GFC-311E US EPA Approval Gas filter correlation method (IR method) High sensitivity measurement enabled with multi-reflection cell Easy-to-use touch panel Meas. range 0 - 5, 0 - 10, 0 - 20, 0 - 50, 0 - 100 ppm

Created on: 21 January 2014

Ozone Analyzer GUX-313E US EPA Approval Continuous measurement of O3 concentration by using UV photometry method Easy-to-use touch panel Meas. range 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm