DKK-TOA DVP-03
|
|
Designed for oil refinery
Measures vapor pressure of petroleum products like gasoline
Vapor pressure is measured by measuring static pressure of the sample that is jetting out from the nozzle at the constant temperature
Measurement result attained via Reid method for vapor pressure
Meas. range
0.01 - 1 MPa abs 0 - 0.15 MPa abs
|
Vapor Pressure Analyzer
|
|
|
DKK-TOA FMS-4
|
|
Fluoride Ion Monitor FMS-4
Simple measurement with just an ion electrode
Enables continuous fluoride ion measurement of discharged industrial wastewater
By adding ionic strength adjustment solution part of nonionic fluoride is measurable
Automatic cleaning and calibration function ensures stable measurement
Easy-to-use touch panel
Meas. range
0.1 - 10/0.2 - 20/1 - 100/10 - 1000 mg/L |
Simplified Fluoride Ion Monitor
|
|
|
DKK-TOA ICA-2000 Series
|
|
Compact main unit holding up to 3 pumps and 2 detector units
Simple system expansion by optional combined pump-detector unit installation
Remote data monitoring capability due to LAN based main unit/PC control signal connection
PC linked pos+/neg- ion 2-channel real-time chromatograph data display and report printout
Non-metal pump for post column reactor is available
Meet a wide range of water supply measurement needs such as cyanide/bromate, chlorate, etc.
High sensitivity analysis... |
Ion Chromatograph
|
|
|
DKK-TOA DO-31P
|
|
DO electrodes for incubator bottles and stirring-free DO electrodes available
Power-saving design; rechargeable battery adaptable
Waterproof design (IP67: 1m depth, up to 30mins)
Data storage up to 1000 points
Meas. range
0 - 20.00 mg/L (0 - 50.0 mg/L)* 0 - 200% (0 - 500%)* *When the high-concentration membrane is used (optional) 0 - 50℃ |
Handheld DO Meter
|
|
|
DKK-TOA HSCA-2000
|
|
Designed for oil refinery
Enables low-concentration measurement ranged 0 - 10 ppm
Adopts credible energy-dispersive X-ray spectroscopy method
Simple composition (no motor and burner)
Easy-to-use touch panel
Explosion-proof TIIS ExpdⅡBT4 certified
Meas. range
0 - 10 ppm 0 - 500 ppm
|
Process Sulfur Content Analyzer
|
|
|
DKK-TOA GCO-200
|
|
Flue Gas CO/O2 Analyzer GCO-200
CO/O2 analyzer with an electric electrolysis CO sensor and a galvanic battery adapted O2 sensor
Ease of maintenance, cost reduction attainable with simple constructed unit
Meas. range
CO: 0 - 200 to 2000 ppm (setting available at 100 ppm intervals)(assignable) O2: 0 - 25%
|
Flue Gas CO/O2 Analyzer
|
|
|
DKK-TOA NHMS-4
|
|
Simple measurement with just an ion electrode
Enables continuous ammonium ion measurements in discharged industrial wastewater, river and water purification plants
Automatic cleaning and calibration function ensures stable measurement
Easy-to-use touch panel
Low-concentration calibration function available
Meas. range
0.05 - 5/0.1 - 10/1 - 100 mg/L
|
Ammonium Ion Monitor
|
|
|
DKK-TOA SU-300
|
|
Sugar Analyzer SU-300
Simple pretreatment
Simultaneous measurement of 5 kinds of sugar and ethanol, or 7 kinds of sugar alcohol
Pulse amperometric method employed
Automatic analysis and calculation without PC
Front operation and easy maintenance
|
Food-Related Analyzers
|
|
|
DKK-TOA SSD-1610(For Low Concentration)/SSD-1620(For Medium Concentration)
|
|
Compact and piston automated analyzer
Types of detectors available: immersion, drop-in and pipe insertion
Long-life optical model and high reliability
RS-485 interface equipped as standard specification; compatible with Modbus communication system
Meas. range
SSD-1610: 0 - 30/500/1000 mg/L SSD-1620: 0 - 5000/10000/20000 mg/L (3-range, manual switching)
|
Suspended Solids Concentration Analyzer
|
|
|
DKK-TOA LHC-7D
|
|
Electrode Holder with Lift Up Type Jet Cleaner LHC-7D
A detector which can lift up from the sample water and remove fouling from the pH/ORP electrode effectively.
Automatic cleaning system that applies alternate streams of wash water and chemical solution (such as a 5% hydrochloric acid solution) to clean the pH/ORP detector.
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA WQC-24
|
|
Simultaneous measurement of up to 11 items (pH, DO, conductivity, turbidity, temp., salinity, total dissolved solid, specific gravity of sea water, water depth, ORP, chlorophyll, Ions(F-, Cl-, NO3-, Ca2+, K+, NH4+) ● Continuous measurement at depth of 100m ● Diameter of standard sensor module is 45mm ● Up to 1 month data storage |
Multi-Parameter Water Quality Meter
|
|
|
DKK-TOA COL-330
|
|
Measures color of oil products and coloration out of mixed heavy oil from heat converters, etc.
Compact onboard spectroscope allows for a broad range of wavelength measurement
Saybolt color, ASTM color, APHA color measurable
Explosion-proof TIIS ExpdⅡBT4 certified
|
Process Colorimeter
|
|
|
DKK-TOA GNC-224-1
|
|
Flue Gas Hydrogen Chloride Analyzer GNC-224-1
Continuous measurement of flue gas hydrogen chloride concentration produced in incineration plants by ion electrode method
Small size chloride ion electrode and auto-cleaning function equipped
Easy installation and maintenance attained with front panel operation
Meas. Range
0 - (50 - 2000) ppm 0 - (10 - 50) ppm (optional)
|
Flue Gas Hydrogen Chloride Analyzer
|
|
|
DKK-TOA CRM-1600
|
|
Automated intermittent monitoring unit; Spectrometric Method using 1,5-Diphenylcarbazide
Stuck of the electromagnetic valve has been improved with rotating measurement cell
Designed for discharged wastewater of plating factory, river water quality and related fields
Meas. range
0 - 0.5/1.0 mg/L (2-ranges)
|
Hexavalent Chromium Monitor
|
|
|
DKK-TOA ALF-1600
|
|
Continuous measurement of alkalinity data in water purification process by coulometric titration method
Requires only 1/4 reagent volume of existing model
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 50/100 mg/L (ppm) (2-ranges)
|
Alkalinity Analyzer
|
|
|
DKK-TOA MM-60R
|
|
2-Channel model with automatic sensor identification
Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel
0.01/0.001 pH display switchable
Large color graphic LCD display
JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement
USB (Host) and LAN equipped as standard specification
External printer connectable
Multiple sample measuring capability (turntable connection)
Data storage up to 300... |
Dissolved Oxygen Meter
|
|
|
DKK-TOA WQC-22A
|
|
Easy measurement of 6 items (pH, temp., DO, conductivity, turbidity, salinity)
Ideal for applications such as rivers, lakes, dams, etc.
Easy maintenance with cartridge electrode
Measurements at depth of 30m is achievable with specific electrodes
AC/DC 2-way power supply
|
Water Quality Checker
|
|
|
DKK-TOA MAC-355
|
|
pH Meter with Auto Calibration MAC-355
Automatic cleaning and 2-point calibration functions serve long-term reliable pH measurement with just little maintenance
Lift-up type design incorporated with air jet cleaning allows for superior cleaning effect and stable measurement
Self-diagnosis and useful message display
Meas. range
pH: -1 - 15
|
pH Meter with Auto-Calibration/Chemical Cleaner
|
|
|
DKK-TOA U-221
|
|
Alternative model to existing controller such as U-22, U-02, etc.
Same panel cut size, easy installation
Interactive input interface supports auto-calibration and multi-stream
Auto-calibration, self-diagnostic, remote control, communication function equipped
|
Controller
|
|
|
DKK-TOA COD-60A
|
|
The integrated oxidation & titration design and the sequence control function simplified operations
Smaller waste solution (lower than 10mL per measurement)
Real time display of sequence and titration curve
Meas. range
0 - 20.0/40.0/100/200/400/1000 mg/L |
Simplified COD Meter
|
|