AC A
(50/60Hz)
|
40/400mA/400A (TRUE RMS)
|±1%rdg±5dgt
(40/400mA)
|±1%rdg±5dgt
(0~300A)
|±2%rdg
(300.1~399.9A)
|
|
AC A
(WIDE)
|
40/400mA/400A (TRUE RMS)
|±1%rdg±5dgt
[50/60Hz],
|±2.5%rdg±10dgt
[20Hz~1kHz] (40/400mA)
|±1%rdg±5dgt
[50/60Hz],
|±2.5%rdg±10dgt
[40Hz~1kHz] (0~300A)
|±2%rdg
[50/60Hz],
|±5%rdg
[40Hz~1kHz] (300.1~399.9A)
|
|
Frequency Response
|
20Hz~1kHz [40Hz~1kHz:400A]
|
|
Maximum
Circuit Voltage
|
600V AC/DC (between line/neutral)
300V AC/DC (against earth)
|
|
Conductor Size
|
Ø40mm max.
|
|
Safety Standard
|
IEC61010-1 CAT.III 300V Pollution Degree 2
IEC61010-2-032
|
|
Effect of External
Stray Magnetic Field
|
10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
|
|
Withstand Voltage
|
3700V AC for 1 minute
|
|
Response Time
|
Approx. 2 seconds
|
|
Power Source
|
Two R03 or equivalent (DC1.5V) batteries
|
|
Dimensions
|
185(L) × 81(W) × 32(D)mm
|
|
Weight
|
270g approx.
|
|
Accessories
|
9052 (Carrying Case) R03(1.5V) × 2
Instruction Manual
|
|
Optional
|
8004/8008
(Multi-Tran)*
|