AC A
(50/60Hz)
|
20/200mA/2/20/200/500A
|±1.5%rdg±5dgt
(20/200mA/2A)
|±2%rdg±5dgt
(20/200A)
|±2.5%rdg±5dgt
(500A)
|
|
AC A
(WIDE)
|
20/200mA/2/20/200/500A
|±1%rdg±3dgt
[50/60Hz],
|±5%rdg±5dgt
[40~400Hz] (20/200mA/2A)
|±1.5%rdg±3dgt
[50/60Hz],
|±5%rdg±5dgt
[40~400Hz] (20/200A)
|±2%rdg±3dgt
[50/60Hz],
|±5%rdg±5dgt
[40~400Hz] (500A)
|
|
AC V
|
600V
|±2%rdg±5dgt
(50/60Hz)
|±5%rdg±5dgt
(40~400Hz)
|
|
Ω
|
200Ω|±1.5%rdg±5dgt
|
|
Conductor Size
|
Ø40mm max.
|
|
Effect of External
Stray Magnetic Field
Ø15mm 100A
|
10mA AC max.
|
|
Frequency Response
|
40~400Hz
|
|
Output
|
DC200mV against 2000 count
|
|
Withstand Voltage
|
3700V AC for 1 minute
|
|
Power Source
|
6F22(9V) × 1 or AC Adaptor
|
|
Dimensions
|
209(L) × 96(W) × 45(D)mm
|
|
Weight
|
450g approx.
|
|
Accessories
|
7066(Test
Leads)
9072(Carrying Case)
8025(Plug for Output Jack)
6F22 × 1
Instruction Manual
|
|
Optional
|
8004/8008(Multi-Tran)*
8022(AC Adaptor)(110V)
8023(AC
Adaptor)(220V)
7014(Output Probe)
|