|
Fluke Silver Instrument CarePlans For Handheld Instruments
|
|
Repairs are always unexpected, and they can be costly. Keep your Fluke Instruments in top operating condition and control your cost of ownership with a Fluke Silver CarePlan. Fluke CarePlans are easy to purchase and register. Maintain your Fluke handheld in peak operating condition and protect your investment beyond your factory warranty.
Silver CarePlan features
Extended warranty coverage for your instrument
Saves you 90% of the repair price
Calibration included on repairs covered by... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke Silver Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Silver CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years. |
CarePlans & warranties
|
|
|
Fluke Silver Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Silver CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Silver CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
One performance check included during your extended warranty period
Full... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke SCC198 Automotive Troubleshooting Kit (190 Series)
|
|
The SCC198 Automotive troubleshooting kit includes:
C190 Hard-shell Carrying Case for 190-Series ScopeMeter
SW90W FlukeView ScopeMeter Software package
OC4USB Serial Interface Cable for connecting the ScopeMeter to a (notebook) PC
STL90 Shielded Test Leads (1 red & 1 gray) with 2 ground leads
Four Backprobe pins (1 red, 1 gray, 2 black),
Four 4 mm Tip adapters (1 red, 1 gray, 2 black),
AC85A Sets of Alligator Clips (Four pieces, 1 red, 1 gray, 2 black)
C75 Softcase, for... |
Options
|
|
|
Fluke SCC128 Automotive Troubleshooting Kit (120 Series)
|
|
The SCC128 Automotive troubleshooting kit includes:
C120 Carrying Case for 120-Series ScopeMeter
SW90W FlukeView ScopeMeter Software package
OC4USB Serial Interface Cable for connecting the ScopeMeter to a (notebook) PC
STL90 Shielded Test Leads (red & gray) with 2 ground leads
Four Back probe pins (1 red, 1 gray, 2 black),
Four 4 mm Tip adapters (1 red, 1 gray, 2 black)
AC85A Sets of Alligator Clips (Four pieces, 1 red, 1 gray, 2 black)
TL24 Ground lead with banana plugs (1... |
Options
|
|
|
Fluke RS400 Probe Accessory Replacement Kit For VPS400 Series Probes
|
|
Compatible with: VPS410B, VPS410G, VPS410R, and VPS410V |
Test Leads, Probes, Clips
|
|
|
Fluke RPM80 Inductive Pick-Up/External Trigger
|
|
Provides RPM readings |
Automotive Accessories
|
|
|
Fluke RLD2 Leakage Detector HVAC/R Flashlight
|
|
Six UV LEDs (395 nm wavelength) detect leak detection dyes
Laser pointer clearly locates center of the UV field for accuracy
Three LED flashlight with 100,000 hour LED life
Operating temperature 0 °C to 50 °C
Four operating modes: flashlight, UV light, laser light, UV/laser light combination
Convenient detachable key chain carabineer and AAA battery included
|
Leak Detectors
|
|
|
Fluke PV350 Pressure Vacuum Module
|
|
Compatible with all Fluke and most popular DMMs
Digital pressure and vacuum measurements in a single module
Transducer sealed in 316 stainless steel compatible with variety of liquids and gases
Measures vacuum to 76 cm Hg
Displays results in English (psig of Hg) or metric (kPa or cm Hg) units
Measures pressure to 3447 kPa (500 psig)
One year warranty
|
Automotive Accessories
|
|
|
Fluke Priority Gold Instrument CarePlans For Handheld Instruments
|
|
Repairs are always unexpected, and they can be costly. Keep your Fluke Instruments in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Fluke CarePlans are easy to purchase and register. Maintain your Fluke handheld in peak operating condition and protect your investment beyond your factory warranty. |
CarePlans & warranties
|
|
|
Fluke Priority Gold Instrument CarePlans For Handheld Instruments
|
|
Repairs are always unexpected, and they can be costly. Keep your Fluke Instruments in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Fluke CarePlans are easy to purchase and register. Maintain your Fluke handheld in peak operating condition and protect your investment beyond your factory warranty.
Gold CarePlan features
Includes annual calibration in three days
Offers up to 70% off of factory calibration prices
Free repairs with guaranteed five day... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke Priority Gold Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years. |
CarePlans & warranties
|
|
|
Fluke Priority Gold Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Priority Gold CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
Loaner camera on extended repair
One NIST traceable calibration included... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke PM9092/001 50 Ohm Coaxial BNC cable set (3 x 0.5m)
|
|
50 Ohm Coaxial BNC cable set, 3 x 0.5 m.
Three colored BNC male connectors (red, gray, and black) for easy identification.
|
Cables & Hardware
|
|
|
Fluke PM9091/001 50 Ohm Coaxial BNC cable set (3 x 1.5m)
|
|
Each set consists of three black cables with colored BNC male connectors (red, gray and black) for easy identification
Cable length is 1.5 m
Maximum Signal Voltage: 300 V rms
Maximum Voltage to Ground: 600 V rms CAT III per IEC 61010-031
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
|
Options
|
|
|
Fluke PM9082001 Dual Banana Plug (female) to Male BNC Adapter
|
|
The set consists of two adapters
One red (signal) and one black (ground) 4-mm banana contact
Maximum Signal Voltage: 600V rms
Maximum Voltage to Ground: 600V rms. CAT III per IEC 61010-031
|
Options
|
|
|
Fluke PM9081001 Dual Banana Plug (male) to Female BNC Adapter
|
|
Dual Banana Plug 4 mm male to female BNC Adapter
Consists of two adapters
Maximum Signal Voltage: 300V rms
Maximum Voltage to Ground: 600V rms
CAT III per IEC 61010-031
|
Options
|
|
|
Fluke PM9080 Optically Isolated RS-232 Adapter
|
|
Safety designed serial interface for digital hard-copy output to serial printer or remote control and data exchange with a PC.
Compatible with all Fluke ScopeMeter® test tools, with Power Quality Analyzers, Graphical MultiMeters and MultiFunction Counters.
Hard Copy: ScopeMeter test tools support Epson FX/LQ Series, LaserJet and DeskJet compatible printers
Remote control: Waveforms, Scope and Meter measurements, Front Set-ups and performance verification/calibration
Transfer rate:... |
Cables & Hardware
|
|
|
Fluke PM9080 Optically Isolated RS-232 Adapter
|
|
Safety designed serial interface for digital hard-copy output to serial printer or remote control and data exchange with a PC.
Compatible with all Fluke ScopeMeter® test tools, with Power Quality Analyzers, Graphical MultiMeters and MultiFunction Counters.
Hard Copy: ScopeMeter test tools support Epson FX/LQ Series, LaserJet and DeskJet compatible printers
Remote control: Waveforms, Scope and Meter measurements, Front Set-ups and performance verification/calibration
Transfer rate:... |
Batteries, Charges and Adapters
|
|
|
Fluke PM8907 Line Voltage Adapter/Battery Charger
|
|
Mains (Line Voltage) - 801 (Europe) 230V ± 10% - 803 (North America) 120V ± 10% - 804 (United Kingdom) 230V ± 10% - 806 (Japan) 100V ± 10% - 807 (Australia) 240V ± 10% - 808 (Universal) switchable 115V± 15% or 230V ± 15% - 808 is equipped with a male receptacle plug that must be connected to a line cord appropriate for local use.
Line cord not included
A North American line plug adapter is included
|
Batteries, Charges and Adapters
|
|