Tenmars TM-28E_TRMS AC/DC WATT Clamp Meter
|
|
Model No.: : TM-28E
Product Description
CAT III 600V 3-3/4 digit LCD, Backlit Display with maximum reading of 4000. High-speed bargraph. True-Rms. Watt measurement: 400KW Data Hold, Peak Hold, Min/Max, and Zero functions. AC/DC volts, AC/DC current, Resistance, Frequency, Watts, Continuity. Autoranging. Relative (REL) zero adjust. Maximum conductor size 35mm. Low battery indication. Overload indication. Continuity buzzer. Auto power off. |
Clamp Meter
|
|
|
Tenmars TM-13E_AC/DC Clamp Meter
|
|
Model No.: : TM-13E
Product Description
CAT III 600V 3-3/4 digit LCD with Analog Bargraph. Display Counts: 4000. Low battery indication. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. |
Clamp Meter
|
|
|
Tenmars TM-27E AC/DC True RMS
|
|
Model No.: : TM-27E
Product Description
CAT III 600V 3-3/4 digit LCD, Backlit Display with maximum reading of 4000. True-Rms. Data Hold, Min/Max, functions. AC/DC volts, AC/DC current, Resistance, Frequency, Continuity. Autoranging. Relative (REL) zero adjust. Maximum conductor size 35mm. Low battery indication. Overload indication. Continuity buzzer. Auto power off. |
Clamp Meter
|
|
|
Tenmars TM-12E AC Clamp Meter
|
|
Model No.: : TM-12E
Product Description
CAT III 600V 3-3/4 digit LCD with Analog Bargraph. Display Counts: 4000. Auto Ranging. Auto power off. (after 30 minutes). High speed bargraph. Data Hold and Range Hold keys. Test Ranges: ACV, ACA, DCV, Resistance, Frequency, Continuity. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. |
Clamp Meter
|
|
|
Tenmars TM-16E AC Clamp Meter
|
|
Model No.: : TM-16E
Product Description
CAT III 600V 3-1/2 digit LCD with maximum reading of 2000. Data Hold. AC volts, DC volts, AC current, Resistance, Continuity, Diode ranges. Autoranging. Maximum conductor size 30mm. Low battery indication. Continuity buzzer. Auto power off. |
Clamp Meter
|
|
|
Tenmars YF-8070 AC Clamp Meter
|
|
Model No.: : YF-8070
Product Description
CAT II 600V 3-1/2 digit LCD with maximum reading of 2000. AC voltage range: 200V, 750V. AC current range: 20A, 200A, 600A. Resistance measurement to 2000 ohms. Data Hold, Peak Hold. Test Ranges: ACV, ACA, Resistance, Freq, Continuity. Frequency. (non-contact frequency measurement. Low battery indication. |
Clamp Meter
|
|
|
Tenmars YF-8030A AC/DC Clamp Meter
|
|
Model No.: : YF-8030A
Product Description
CAT III 1000V 3-3/4 digit LCD with maximum reading of 4000. Overload indication. Automatic polarity. Low battery indication. AC voltage range: 0 to 750V. AC current range: 0 to 1200A. DC voltage range: 0 to 1000V. DC current range: 0 to 1200A Min/Max, Zero (REL). Test Ranges: ACV, ACA, DCV, DCA, Resistance, Frequency, Diode, Capacitance, Continuity. Auto Power Off. |
Clamp Meter
|
|
|
Tenmars YF-8050 AC Clamp Meter
|
|
Model No.: : YF-8050
Product Description
CAT III 1000V 3-3/4 digit LCD display with maximum reading of 4000. Overload indication. Low battery indication. AC voltage range: 0 to 750V. AC current range: 0 to 1000A. Peak Hold. Test Ranges: ACV, ACA, Resistance, Frequency, Continuity. Non-contact frequency measurement. Auto Power Off. Double Injection outer case. |
Clamp Meter
|
|
|
Tenmars TM-1014 AC Clamp Meter
|
|
Model No.: : TM-1014
Product Description
CAT III 600V 3-3/4 digit LCD Backlit Display, with Analog Bargraph. Display Counts: 4000. Auto Ranging. Data Hold and Min/Max functions. Test Ranges: ACV, ACA, DCV, Resistance, Frequency, Continuity. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. Double injection outer case. |
Clamp Meter
|
|
|
Tenmars TM-1012 AC Clamp Meter
|
|
Model No.: : TM-1012
Product Description
CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case. |
Clamp Meter
|
|
|
Tenmars YF-8160 100A Leakage AC Clamp Meter
|
|
Model No.: : YF-8160
Product Description
- CAT III 600V. - Maximum conductor size : 30mm. - Display counts : 4,000. - Test ranges: ACV (600V), ACA (100A), Ohm, Continuity. - Leakage Current Test. |
Clamp Meter
|
|
|
Tenmars TM-14E AC/DC Current Transducer
|
|
Model No.: : TM-14E
Product Description
CAT III 600V AC/DC current ranges 40A and 400A. Maximum conductor size 30mm. Low battery indication. |
Clamp Meter
|
|
|
Tenmars TM-15E AC Current Transducer
|
|
Model No.: : TM-15E
Product Description
CAT III 600V AC current range 400A. Maximum conductor size 30mm. |
Clamp Meter
|
|
|
Tenmars YF-800 AC Analog Clamp Meter
|
|
Model No.: : YF-800
Product Description
Rotary scale presents one range at a time.. Function Key: Pointer lock switch. AC Voltage Ranges: 150V, 300V, 600V. AC Current Ranges: 6A, 15A, 60A, 150A, 300A. Resistance. Max. Conductor Size: 42mm. Zero adjust. Inter magnetic version to prevent interference from magnet fields. |
Clamp Meter
|
|
|
Tenmars TM-1004 400A-AC/DC Current Transducer
|
|
Model No.: : TM-1004
Product Description
CAT III 600V AC/DC current ranges 40A and 400A. Maximum conductor size 30mm. Low battery indication. |
Clamp Meter
|
|
|
Tenmars YF-8020 AC Clamp Meter
|
|
Model No.: : YF-8020A
Product Description
3-1/2 digit LCD with maximum reading of 2000. AC voltage range: 200V, 750V. AC current range: 20A, 200A, 600A. Resistance measurement to 2000 ohms. |
Clamp Meter
|
|
|
TES/PROVA Clamp meters
|
|
All kinds of Taiwanese Clamp meters. Latest range.
|
Clamp meters
|
|
|
TEN001-YF-8160 100A LEAKAGE AC CLAMP METER WITH NICKLE STEEL RING
|
|
DISPLAY:
- 3¾ digits LCD with maximum reading 4000.
- Overload indication.
- Low battery indication.
FUNCTIONS:
- Peak Hold.
- Leakage Current Test.
- Test ranges: ACV (600V), ACA (100A) , Ohm, Continuity.
- Continuity test below 100Ohm will have buzzer sound.
- Alternative for supply frequency.
- With LPF (Low Pass Filter) function, 50/60Hz and wide frequency function (40~1KHz).- Maximum conductor size : 30mm.- Dimension : 250mm x 85mm x 35mm.
|
Clamp meters
|
|
|
TEN005-TM-10124V3 ECONOMICAL AC CLAMP METER ACA400 ACV600
|
|
CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case. |
Clamp meters
|
|
|
TEN006-TM-1018V3 AC/DC CLAMP METER (CUM AUTOMOTIVE CLAMP)
|
|
CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, DCA, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case. |
Clamp meters
|
|