By Brands

Brands

  • Filter
Created on: 20 January 2014

JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement  Built-in pure water temperature compensation  USB (Host) and LAN equipped as standard specification  Compliant with USP<645> requirements Meas. range 0 - 200.0 S/m 0 - 20.00 MΩ・m Chloride 0 - 4.00% Concentration 0 - 200% 0 - 100.0 degrees C

Created on: 20 January 2014

2-channel type, simultaneous measurement and display of pH/conductivity Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points PC and external printer connectable  Measurement items pH, ORP, conductivity, resistivity, salinity, temperature (ORP electrodes sold separately)

Created on: 21 January 2014

Compact DIN 96 size design Auto-detection of electrode deterioration Automated self-diagnosis of fault (burn-out output) Alterable alarm contact signal (4-point) 2-channel output (RS-232 optional) Meas. range: HBM-100A: pH; -1 - 15 HBM-102A: ORP; -2000 - +2000 mV

Created on: 21 January 2014

Compact DIN 96 size Temperature compensation computed by a microcomputer  Cell constant value adjustable depends on customers' need Water temperature displayable Power supply: AC90 - 264V, 50/60Hz Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm

Panel Type Electromagnetic Conductivity Analyzer MBM-100A Compact DIN 96 size Accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) 2-point contact signal, 4 - 20mA output (RS-232 optional)    Meas. range Minimum : 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm

Immersion/Drop-In Type DO Holder OC-711 / OC-950 Lightweight PVC holder; length of immersion type holder: 0.3 - 3.5 m, length of stainless steel protection pipe for drop-in type holder: 2 - 6 m Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)

Created on: 21 January 2014

Compact and lightweight model in accordance with DIN standard DC 24V power supply designed for 4-point alarm and 2-wire transmitters Often used as a receiver of 2-wire or 4-wire transmitter (such as pH/ORP meters, conductivity analyzers and DO meters)  Meas. range pH meter: pH; 0 - 14 70divisions (to be specified otherwise)

Created on: 21 January 2014

Measures residual chlorine (total or free) happened in the water chlorination process Continuously measurement with polarographic method 1/5 reagent requirement of existing models RS-485 equipped as standard specification; compatible with Modbus communication system Freely mountable on walls, racks, etc. for the compact lightweight design Meas. range 0 - 0.5/1.0 to 0 - 5/10 mg/L (ppm) (2-range)