MagMount-1
|
|
The MagMount-1 is a magnetic holder for use with the PR140, HiTemp140 series and 1000 series data loggers. The device can be placed in environments from -80°C to +80°C, making it ideal for use in refrigerators, freezers, and incubators. |
Mounting Kits
|
|
|
Megger 210170 Hand-Cranked Analog Major Megger Insulation Tester
|
|
est Voltages of 100/250/500/1000 VDC
Insulation resistance measurements up to 20 GΩ
0 to 5000Ω Continuity Range
Guard terminal to eliminate surface leakage current
Hand-Cranked
Large easy-to-read scale
|
Megger
|
|
|
Megger 210400 and 210415 5 and 15 kV Megohmmeter
|
|
210400: 5 kV, 100 GΩ
210415: 15 kV, 300 GΩ
Zero-start, high-voltage interlock
Shielded, high-voltage output cable permanently connected to the instrument
Redundant grounding connections
Easy-to-follow, color-coded meter scales
Continuously variable test voltage
Rugged field construction
Circuit-breaker protection
|
Megger
|
|
|
Megger 210400 and 210415 5 and 15 kV MegohmmeterMegger 210400 and 210415 5 and 15 kV Megohmmeter
|
|
210400: 5 kV, 100 GΩ
210415: 15 kV, 300 GΩ
Zero-start, high-voltage interlock
Shielded, high-voltage output cable permanently connected to the instrument
Redundant grounding connections
Easy-to-follow, color-coded meter scales
Continuously variable test voltage
Rugged field construction
Circuit-breaker protection
|
Megger
|
|
|
Megger 210600 Digital Major Megger Insulation Tester (Battery operated)
|
|
Test Voltages of 100/250/500/1000 VDC
Insulation resistance measurements up to 1999 MΩ
0 to 600 VAC Measuring Range
Guard terminal to eliminate surface leakage current
Battery Operated
Autoranging
Large easy-to-read 3Ω LCD display
|
Megger
|
|
|
Megger 212159 MJ159 Major Megger Hand-Cranked Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
Available in alternate configurations:
212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
212459 - Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests
212559 - Dual operation 120 V 50/60... |
Megger
|
|
|
Megger 212359 MJ359 Major Megger Line/Hand-Cranked Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
Available in alternate configurations:
212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
212459 - Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests
212559 - Dual operation 120 V 50/60... |
Megger
|
|
|
Megger 212459 MJ459 Major Megger Battery Powered Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests
Available in alternate configurations:
212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
212559 - Dual operation 120 V 50/60... |
Megger
|
|
|
Megger 212559 MJ559 Major Megger Line/Battery Powered Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells
Available in alternate configurations:
212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
212459 - Six IEC LR6 cells... |
Megger
|
|
|
Megger 21805-3CL 500 V Midget Insulation Tester
|
|
Test Voltage of 500 VDC
Insulation Resistance 0-200 Megohms
Easy-to-Read Analog Scale - No Multipliers
Automatic Discharge of Item Under Test
|
Megger
|
|
|
Megger 220005 and 220015 5 and 15 kV DC Dielectric Test Set
|
|
Continuously variable test voltage
Rugged field construction
Compact and portable
|
Megger
|
|
|
Megger 220005 and 220015 5 and 15 kV DC Dielectric Test Set
|
|
Continuously variable test voltage
Rugged field construction
Compact and portable
|
Megger
|
|
|
Megger 230315 0-3 kV AC High-Pot Tester
|
|
Ground continuity check of three-wire devices with high-voltage interlock
Front-panel adjustable leakage current trip from 0.3 to 12 mA
One-second or continuous testing
Automatic failure shutdown, with visual and audible alarms
Recessed high-voltage connections
Front-panel NEMA 5-15R three-prong receptacle
Zero start/reset in event of failure
Meets UL 120-k½ requirement
Available in alternate configurations:
230415 - 0-4 kV AC applied test voltage
230425 - 0-4 kV AC and 0-5 kV DC... |
Megger
|
|
|
Megger 230415 0-4 kV AC High-Pot Tester
|
|
Ground continuity check of three-wire devices with high-voltage interlock
Front-panel adjustable leakage current trip from 0.3 to 12 mA
One-second or continuous testing
Automatic failure shutdown, with visual and audible alarms
Recessed high-voltage connections
Front-panel NEMA 5-15R three-prong receptacle
Zero start/reset in event of failure
Meets UL 120-k½ requirement
Available in alternate configurations:
230315 - 0-3 kV AC applied test voltage
230425 - 0-4 kV AC and 0-5 kV DC... |
Megger
|
|
|
Megger 230425 0-4 kV AC and 0-5 kV DC High-Pot Tester
|
|
Front-panel adjustable leakage current trip from 0.3 to 12 mA
One-second or continuous testing
Automatic failure shutdown, with visual and audible alarms
Recessed high-voltage connections
Zero start/reset in event of failure
Meets UL 120-k½ requirement
Available in alternate configurations:
230315 - 0-3 kV AC applied test voltage
230415 - 0-4 kV AC applied test voltage
|
Megger
|
|
|
Megger 235303 Tool and Appliance Tester
|
|
Full conformance to latest UL and ANSI test requirements.
Meter reading - not just "good/bad" indications.
Ground check bypass switch permits testing of two wire or double-insulated devices.
Removable lid with metal tray holds device under test.
Front-panel NEMA 5-15 output receptacle, with adapters available to convert to a 20-ampere plug or twist lock up to 30-amperes
|
Megger
|
|
|
Megger 247000, 247001, and 247002 Digital Low Resistance Ohmmeters
|
|
Resolution to 0.1 µΩ on 599.9 µΩ range
Standard accuracy of ±0.25%
Digital Readout
|
Megger
|
|
|
Megger 514242-1 67 to 235 kV DETEX Voltage Detector
|
|
Detector rated for transmission line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line... |
Megger
|
|
|
Megger 514242-2 200 to 550 kV DETEX Voltage Detector
|
|
Detector rated for transmission line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line... |
Megger
|
|
|
Megger 514360-1 2.3-7.2 kV DETEX Voltage Detector
|
|
Electronic voltage detector for use on distribution line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line pole
514242-1 - 67 to 235 kV, Spline... |
Megger
|
|