TES-46 CAT-5 Lan Cable Tester
|
|
Tests : UTP. FTP. Coax cables, two, three, or four wire pairs in twisted pair cables and test all category UTP cables and hardware.
Verify end-to-end connectivity per EIA/TIA 568 wiring standard.
Detects wiring problems : Opens, Shorts, miswires (Crossed, Reversed, Split pair).
Locates wiring/connection errors (distance to the open or shout)
Measures cable length
Easy to use only : One button to select the test and two lines characters LCD display.
Low battery, Auto power off, long... |
Lan Cable Tester
|
|
|
TES-52 Sound Level Meter
|
|
0.1dB Resolution
Range from 30 to 130dB
A&C frequency weighting
Fast/Slow Dynamic characteristic
Maximum with Elapsed time
Manual data memory and read
5Selectable Ranges
Bargraph Indication
Logging Function (99 Sets)
|
Sound Level Meter
|
|
|
TES-593 ElectroSmog Meter
|
|
Frequency range 10MHz to 8.0GHz
3 axis isotropic measurements of EMF
Non-directional (isotropic) measurement with three-channel measurement probe
High dynamic range
Configurable alarm threshold and memory function
Easy & safety to use
High frequency (RF) electromagnetic wave field strength measurement
Mobile phone base station antenna radiation power density measurement
Wireless communication applications (CW, TDMA, GSM, DECT)
RF power measurement for... |
EMF Tester
|
|
|
TES-6830+6801 Power and Harmonics Analyzer (100A) TES-6830+6802 Power and Harmonics Analyzer (1000A) TES-6830+3007 Power and Harmonics Analyzer ( 3000A)
|
|
Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS Value (V 123 and L 123 )
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
Display of 35 Parameters in One Screen(3P4W)
Programmable CT (1 to 600) and PT (1 to 3000) Ratios
Display of Overlapped Voltage and Current Waveform
2.4M... |
3 Phase Power Analyzer
|
|
|
TES-92 ElectroSmog Meter
|
|
50 MHz to 3.5 GHz frequency range.
For isotropic measurements of electromagnetic fields.
Non-directional (isotropic ) measurement with three-channel measurement probe.
High dynamic range due to three-channel digital results processing.
Configurable alarm threshold and memory function.
Easy to use
High frequency (RF) electromagnetic wave field strength measurement.
Mobil phone base station antenna radiation power density measurement.
Wireless communication applications (CW , TDMA ,... |
EMF Tester
|
|
|
Testo 0133 0010 Internal Filter for 330/335/342/346 Measuring Instruments
|
|
Testo 0133 0010 Internal Filter for 330/335/342/346 Measuring Instruments |
Filters
|
|
|
Testo 0192 0265 Open plastic cap for Humidity Transmitters
|
|
Plastic open protective cap
Fast reaction time at flow velocities less than 7 m/s (not suitable for dusty atmospheres)
|
Caps Cones & Funnels
|
|
|
Testo 0363 1712 Smelting Probe Thermocouple
|
|
TC with tube and plug NiCr-Ni
Space measuring tip for smelting probe
Measuring range: -200 to 1250 ° C
|
Adapters
|
|
|
Testo 0390 0061 Spare O2 Sensor for 330-1 LL/-2 LL Flue Gas Analyzer
|
|
Spare O2 measuring cell
For Testo 330-1 LL/-2 LL flue gas analyzer
|
Sensors
|
|
|
Testo 0390 0074 NO Replacement Sensor (0-3,000 PPM)
|
|
Spare NO measuring cell
For Testo 330-1 LL/-2 LL flue gas analyzer
|
Sensors
|
|
|
Testo 0390 0090 CO Replacement Sensor w/H2 Compensation, 0 - 8000 ppm for 330-2 LL Flue Gas Analyzer
|
|
CO replacement measuring cell
0 to 8000 ppm range
For 330-2 LL flue gas analyzer
|
Sensors
|
|
|
Testo 0390 0092 O2 Sensor, for 330-1/-2/-3 & 327-2 Flue Gas Analyzer
|
|
O2 measuring sensor for 330-1/-2/-3 and 327-2 flue gas analyzers |
Sensors
|
|
|
Testo 0390 0094 NO Low Range Replacement Sensor for 330-1 LL/-2 LL Flue Gas Analyzer
|
|
No low range replacement sensor
0-300 ppm, 0.1 ppm resolution
For 330-2/-3 and 327-2 flue gas analyzer
|
Sensors
|
|
|
Testo 0390 0109 Spare CO Replacement Sensor w/H2 Compensation for 330-2/-3 and 327-2
|
|
Spare CO replacement measuring cell with H2 compensation
For 330-2/-3 and 327-2 flue gas analyzer
8000 ppm, 1 ppm resolution
|
Sensors
|
|
|
Testo 0390 0118 CO Sensor without H2 Compensation, 0 to 4000 ppm for 330-1 LL Flue Gas Analyzer
|
|
CO measuring cell without H2 compensation
0 to 4000 ppm
For 330-1 LL flue gas analyzer
|
Sensors
|
|
|
Testo 0390 0168 Self Service Replacement CO Measuring Sensor for 325-1 and 325-3 Flue Gas Analyzer
|
|
Self service replacement CO measuring sensor
For 325-1 and 325-3 flue gas analyzer
|
Sensors
|
|
|
Testo 0393 0051 CO Sensor for 330G LL Flue Gas Analyzers
|
|
CO measuring cell
For 330G LL flue gas promo set
|
Sensors
|
|
|
Testo 0409 0063 15' Probe Extension Cable
|
|
Temperature Probe extension cable
PUR coating material
Between plug-in head cable and instrument
15 foot Length
|
Cables
|
|
|
Testo 0409 0178 5.9' Data Transfer Cable
|
|
RS232 data transfer cable
Connects instrument to PC (1.8m) for data transfer
|
Cables
|
|
|
Testo 0409 0202 2.5m Connector Cable for Pressure Probes
|
|
Connector cable
For the following pressure probes:
0638 1741
0638 1841
0638 1941
0638 2041
0638 2141
2.5m Length
|
Cables
|
|