Megger 230415 0-4 kV AC High-Pot Tester
|
|
Ground continuity check of three-wire devices with high-voltage interlock
Front-panel adjustable leakage current trip from 0.3 to 12 mA
One-second or continuous testing
Automatic failure shutdown, with visual and audible alarms
Recessed high-voltage connections
Front-panel NEMA 5-15R three-prong receptacle
Zero start/reset in event of failure
Meets UL 120-k½ requirement
Available in alternate configurations:
230315 - 0-3 kV AC applied test voltage
230425 - 0-4 kV AC and 0-5 kV DC... |
Megger
|
|
|
Megger 230425 0-4 kV AC and 0-5 kV DC High-Pot Tester
|
|
Front-panel adjustable leakage current trip from 0.3 to 12 mA
One-second or continuous testing
Automatic failure shutdown, with visual and audible alarms
Recessed high-voltage connections
Zero start/reset in event of failure
Meets UL 120-k½ requirement
Available in alternate configurations:
230315 - 0-3 kV AC applied test voltage
230415 - 0-4 kV AC applied test voltage
|
Megger
|
|
|
Megger 235303 Tool and Appliance Tester
|
|
Full conformance to latest UL and ANSI test requirements.
Meter reading - not just "good/bad" indications.
Ground check bypass switch permits testing of two wire or double-insulated devices.
Removable lid with metal tray holds device under test.
Front-panel NEMA 5-15 output receptacle, with adapters available to convert to a 20-ampere plug or twist lock up to 30-amperes
|
Megger
|
|
|
Megger BITE2 and BITE2P Battery Impedance Tester
|
|
Determines condition of lead-acid and NiCd Cells up to 7000 Ah
On-board Pass/Warning/Fail Indications
Robust, repeatable instruments
On-line testing
|
Megger
|
|
|
Megger BITE2 and BITE2P Battery Impedance Tester
|
|
Determines condition of lead-acid and NiCd Cells up to 7000 Ah
On-board Pass/Warning/Fail Indications
Robust, repeatable instruments
On-line testing
|
Megger
|
|
|
Megger 247000, 247001, and 247002 Digital Low Resistance Ohmmeters
|
|
Resolution to 0.1 µΩ on 599.9 µΩ range
Standard accuracy of ±0.25%
Digital Readout
|
Megger
|
|
|
Megger DETEX Phasing Detectors
|
|
Five Models
Grounded or ungrounded AC system check
Model 510836-1 provides Bright LED indication
|
Megger
|
|
|
Megger 514242-1 67 to 235 kV DETEX Voltage Detector
|
|
Detector rated for transmission line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line... |
Megger
|
|
|
Megger 514242-2 200 to 550 kV DETEX Voltage Detector
|
|
Detector rated for transmission line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line... |
Megger
|
|
|
Megger 514360-1 2.3-7.2 kV DETEX Voltage Detector
|
|
Electronic voltage detector for use on distribution line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line pole
514242-1 - 67 to 235 kV, Spline... |
Megger
|
|
|
Megger 514360-2 4 to 14.5 kV DETEX Voltage Detector
|
|
Electronic voltage detector for use on distribution line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line pole
514242-1 - 67 to 235 kV, Spline fitted for attachment to a universal... |
Megger
|
|
|
Megger 514360-3 11.7 to 36.2 kV DETEX Voltage Detector
|
|
Electronic voltage detector for use on distribution line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot line pole
514242-1 - 67 to 235 kV, Spline fitted for attachment to a universal hot... |
Megger
|
|
|
Megger 514360-4 24.3 to 72.5 kV DETEX Voltage Detector
|
|
Electronic voltage detector for use on distribution line voltages
Continuous monitoring
Electronic model with red LED and audible indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514242-1 - 67 to 235 kV, Spline fitted for attachment to a universal hot... |
Megger
|
|
|
Megger 514440-2 3.6 to 36.5 kV DETEX Voltage Detector
|
|
Voltage detector is designed for indoor testing of grounded ac systems
Continuous monitoring
Electronic model with white LED indication
IEC conformance
Available in alternate configurations:
514360-1 - 2.3 to 7.2 kV, 51-in. telescopic pole
514360-2 - 4 to 14.5 kV, Spline fitted for attachment to a universal hot line pole
514360-3 - 11.7 to 36.2 kV, Spline fitted for attachment to a universal hot line pole
514360-4 - 24.3 to 72.5 kV, Spline fitted for attachment to a universal hot... |
Megger
|
|
|
Megger DETEX Phasing Detectors
|
|
Five Models
Grounded or ungrounded AC system check
Model 510836-1 provides Bright LED indication
|
Megger
|
|
|
Megger DETEX Phasing Detectors-2
|
|
Five Models
Grounded or ungrounded AC system check
Model 510836-1 provides Bright LED indication
|
Megger
|
|
|
Megger 550005B Transformer Turns Ratio Test Set
|
|
Used for testing single phase power and distribution transformers
Design based on precision bridge measuring technique
Available in hand-cranked or line-operated models
Unmatched accuracy (±0.1%) in a portable design
|
Megger
|
|
|
Megger 560060 and 560400 Phase and Motor Rotation Testers
|
|
Complete phase-sequence and motor-rotation testing in one instrument
Ensures correct phase hookup in one easy test
Rugged and portable tester
Performs additional polarity and continuity checks
Motor and Phase Rotation Tester permits the electrical contractor or industrial maintenance electrician to permanently connect and tape the terminals of the motor being installed, without having to first energize the motor by a temporary hookup from a power source, if available, to determine... |
Megger
|
|
|
Megger 569001 Ultrasonic Leak / Corona Detector
|
|
Features compact long-distance directional pickup
Locates gas leaks and corona within inches of the source
Lightweight for easy use, even in remote field locations
Insensitive to high ambient audible noise levels
|
Megger
|
|
|
Megger 656601 Energized Cable Route Tracer
|
|
Locates and traces cables energized with 50/60 Hertz
Three-way swivel detector also measures cable depth
Two sensitivity ranges enable tracing of cables as much as 8 ft deep
Peak and null location methods
Lightweight, battery operated
|
Megger
|
|