Fluke 075-CLKTO 3" (75mm) C-Range Indoor Infrared (IR) Window, Medium Voltage, with Kwik Twist Cover
|
|
Impact resistant viewing pane compliant to ANSI C37.20.2 for indoor switchgear up to 72 kV
CLKTO IR Windows from Fluke use the unique Quadraband multispectral optic, allowing inspection with any camera for total flexibility both now and in the future
Certified by UL and CSA as suitable for Type 1 (Indoor) environment in North America, these C-Range windows are tested to withstand the long term aging effects of UV exposure
The CLIRVU coating—exclusive to Fluke Windows—seals the optic... |
Infrared (IR) Windows
|
|
|
Fluke 075-CLV CLV Infrared Window for indoor low-voltage applications
|
|
Industry’s first and only IR Window tested to UL1558 Low Voltage Switchgear Standard
Certified by UL as suitable for Type 1 (Indoor) environment in North America, these windows are tested to withstand the long term aging effects of UV exposure
The Fluke CLIRVU coating—exclusive to Fluke Windows—seals the optic prior to assembly to protect against moisture degradation
For use on enclosures up to 600 V
Identification plate attached for unique, onsite numbering for rapid location... |
Infrared (IR) Windows
|
|
|
Fluke 100-CLKT 4" (100mm) Infrared (IR) Window with Kwik Twist Cover
|
|
Viewing aperture diameter: 89 mm (2.7 in)
Viewing aperture area: 6322 mm2 (9.79 sq in)
Engineered and tested to withstand electric-arcs up to 50 kA for 30 cycles
Certified by UL & CSA for Type 3/12 (Outdoor) environments in North America and Canada, the C-Range windows are tested to withstand the long term aging effects of UV exposure
Certified by SIRA Certification IP65 (Outdoor) environments in Europe
The CLIRVU coating—exclusive to Hawk IR Windows—seals the optic prior to... |
Infrared (IR) Windows
|
|
|
Fluke CV200 2 in (50 mm) ClirVu Infrared Window with Hand Turn Door Latch
|
|
No more removing the panel door for installation
Work permit requirements and NFPA 70E processes are significantly reduced
Full PPE is often not required so inspections are done faster and more comfortable
Superior arc blast protection:
High temperature silicon gaskets
Mounting and door latches provide high pressure gasket compression
Die cast components are manufactured with the highest strength alloys
Jam nut screws are made from 4037 steel, heat treated to 160,000 psi... |
Infrared (IR) Windows
|
|
|
Fluke CV201 2 in (50 mm) ClirVu Infrared Window with Security Key Door Latch
|
|
No more removing the panel door for installation
Work permit requirements and NFPA 70E processes are significantly reduced
Full PPE is often not required so inspections are done faster and more comfortable
Superior arc blast protection:
High temperature silicon gaskets
Mounting and door latches provide high pressure gasket compression
Die cast components are manufactured with the highest strength alloys
Jam nut screws are made from 4037 steel, heat treated to 160,000 psi... |
Infrared (IR) Windows
|
|
|
Fluke CV300 3 in (75 mm) ClirVu Infrared Window with Hand Turn Door Latch
|
|
No more removing the panel door for installation
Work permit requirements and NFPA 70E processes are significantly reduced
Full PPE is often not required so inspections are done faster and more comfortable
Superior arc blast protection:
High temperature silicon gaskets
Mounting and door latches provide high pressure gasket compression
Die cast components are manufactured with the highest strength alloys
Jam nut screws are made from 4037 steel, heat treated to 160,000 psi... |
Infrared (IR) Windows
|
|
|
Fluke CV301 3 in (75 mm) ClirVu Infrared Window with Security Key Door Latch
|
|
No more removing the panel door for installation
Work permit requirements and NFPA 70E processes are significantly reduced
Full PPE is often not required so inspections are done faster and more comfortable
Superior arc blast protection:
High temperature silicon gaskets
Mounting and door latches provide high pressure gasket compression
Die cast components are manufactured with the highest strength alloys
Jam nut screws are made from 4037 steel, heat treated to 160,000 psi... |
Infrared (IR) Windows
|
|
|
Fluke CV400 4 in (95 mm) ClirVu Infrared Window with Hand Turn Door Latch
|
|
No more removing the panel door for installation
Work permit requirements and NFPA 70E processes are significantly reduced
Full PPE is often not required so inspections are done faster and more comfortable
Superior arc blast protection:
High temperature silicon gaskets
Mounting and door latches provide high pressure gasket compression
Die cast components are manufactured with the highest strength alloys
Jam nut screws are made from 4037 steel, heat treated to 160,000 psi... |
Infrared (IR) Windows
|
|
|
Fluke CV401 4 in (95 mm) ClirVu Infrared Window with Security Key Door Latch
|
|
No more removing the panel door for installation
Work permit requirements and NFPA 70E processes are significantly reduced
Full PPE is often not required so inspections are done faster and more comfortable
Superior arc blast protection:
High temperature silicon gaskets
Mounting and door latches provide high pressure gasket compression
Die cast components are manufactured with the highest strength alloys
Jam nut screws are made from 4037 steel, heat treated to 160,000 psi... |
Infrared (IR) Windows
|
|
|
Fluke Priority Gold Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Priority Gold CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
Loaner camera on extended repair
One NIST traceable calibration included... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke Silver Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Silver CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Silver CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
One performance check included during your extended warranty period
Full... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke Bronze Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Bronze CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Bronze CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
Performance check on needed repair
First-on-Bench priority handling
Discount on... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke Priority Gold Instrument CarePlans For Handheld Instruments
|
|
Repairs are always unexpected, and they can be costly. Keep your Fluke Instruments in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Fluke CarePlans are easy to purchase and register. Maintain your Fluke handheld in peak operating condition and protect your investment beyond your factory warranty.
Gold CarePlan features
Includes annual calibration in three days
Offers up to 70% off of factory calibration prices
Free repairs with guaranteed five day... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke Silver Instrument CarePlans For Handheld Instruments
|
|
Repairs are always unexpected, and they can be costly. Keep your Fluke Instruments in top operating condition and control your cost of ownership with a Fluke Silver CarePlan. Fluke CarePlans are easy to purchase and register. Maintain your Fluke handheld in peak operating condition and protect your investment beyond your factory warranty.
Silver CarePlan features
Extended warranty coverage for your instrument
Saves you 90% of the repair price
Calibration included on repairs covered by... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
Fluke BB120 Shielded Banana to Female BNC Adapter
|
|
Maximum Signal Voltage: 300V rms CAT III per IEC 1010-02-031
Maximum Voltage to Ground: 600V rms. CAT III per IEC 1010-2-031
|
Options
|
|
|
Fluke H3 Clamp Meter Holster
|
|
Fabric holster absorbs shocks and protects meter from rough handling
Built-in pocket for lead storage Convenient belt-loop with snap
One year warranty
|
Options
|
|
|
Fluke PM9081001 Dual Banana Plug (male) to Female BNC Adapter
|
|
Dual Banana Plug 4 mm male to female BNC Adapter
Consists of two adapters
Maximum Signal Voltage: 300V rms
Maximum Voltage to Ground: 600V rms
CAT III per IEC 61010-031
|
Options
|
|
|
Fluke PM9082001 Dual Banana Plug (female) to Male BNC Adapter
|
|
The set consists of two adapters
One red (signal) and one black (ground) 4-mm banana contact
Maximum Signal Voltage: 600V rms
Maximum Voltage to Ground: 600V rms. CAT III per IEC 61010-031
|
Options
|
|
|
Fluke PM9091/001 50 Ohm Coaxial BNC cable set (3 x 1.5m)
|
|
Each set consists of three black cables with colored BNC male connectors (red, gray and black) for easy identification
Cable length is 1.5 m
Maximum Signal Voltage: 300 V rms
Maximum Voltage to Ground: 600 V rms CAT III per IEC 61010-031
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
|
Options
|
|
|
Fluke SCC128 Automotive Troubleshooting Kit (120 Series)
|
|
The SCC128 Automotive troubleshooting kit includes:
C120 Carrying Case for 120-Series ScopeMeter
SW90W FlukeView ScopeMeter Software package
OC4USB Serial Interface Cable for connecting the ScopeMeter to a (notebook) PC
STL90 Shielded Test Leads (red & gray) with 2 ground leads
Four Back probe pins (1 red, 1 gray, 2 black),
Four 4 mm Tip adapters (1 red, 1 gray, 2 black)
AC85A Sets of Alligator Clips (Four pieces, 1 red, 1 gray, 2 black)
TL24 Ground lead with banana plugs (1... |
Options
|
|