"My third deal with them. Price acceptable. Service Excellent. They have helped us to source several products that make it possible for us to fulfill our orders before deadline! Beginning I was a bit worry but they made it! My Customer-Telekom are happy with all the products! Will buy again! - As-per

"Good Service" SAAG GROUP

DELIVER BY


GRA007-GL220 10 Channel handy-type logger PDF Print E-mail

Instrument GL220

 

10 isolated channels, each with multifunction input
Its compact size contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. The GL220s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage.


10 isolated channels, each with multifunction input
TOP
Maximum sampling rate of up to 10ms
Provides faster sampling rates for voltage measurements. Can achieve 10ms sampling interval when limiting the number of channels in use.


Sampling interval

10ms

20ms

50ms

100ms

1s

Number of channels

1

2

5

10

10

Measuring*2

Voltage

X

X

X

X

X

Temperature

N/A

N/A

N/A

X

X

X: selection is available, N/A: selection is not available.
*2:
For humidity measurements, the 0-1V range and scaling function are used to display results directly in Relative Humidity. Sampling rate limitations are same as those for voltage measurement.
External sampling function
Captured data can be synchronized with external timing signals when the external sampling rate function is used.*3
*3:
The Logic/alarm cable, (B-513 option), is needed to connect the alarm output ports.
TOP
Large easy-to-read 4.3-inch wide TFT color LCD
Utilises a bright clear 4.3-inch wide TFT color LCD monitor (WQVGA: 480 x 272 dots). Makes it easy to read data in waveform or digital form and to check your measurement parameter settings. The background color of the screen can be set to black or white.


Waveform display (Analog + Digital)
Waveform display (Analog + Digital)

Dual display (Current + Past)
Dual display (Current + Past)

Waveform display (Analog only)
Waveform display (Analog only)

Digital display
Digital display

TOP
Built-in 2GB Flash Memory
Built-in 2GB Flash Memory for reliable long term measurement
The 2GB Flash Memory enables secure long term data measurement without using an external storage device. Data is retained even when power is turned off because flash memory is used.
Capturing time*4 (10 Analogue channels being used.)


Sampling interval

10ms*5

50ms*5

100ms

200ms

500ms

1s

2s

Built-in 2GB Flash memory

38 days

83 days

97 days

194 days

485 days

971 days

9,714 days

512MB USB memory stick*6

9 days

21 days

24 days

49 days

124 days

248 days

2,481 days

*4:
The above figures are approximate.
*5:
The sampling rate is limited by the number of channels in use. (10ms: 1ch, 50ms: 5ch)
*6:
Standard USB memory devices without high-end functions such as fingerprint recognition are required.
Hot-swappable USB memory sticks
Also supports popular USB memory sticks for external storage. The GL220 saves measured data directly to USB memory sticks. USB memory sticks can be replaced during measurement without data loss.
Hot-swappable USB memory sticks
Ring memory function
The most recent data is saved when internal memory or external memory is configured in ring memory mode. Captured data size in ring memory mode is limited to 1/3 of available memory.
TOP
Easy operation and device setup
Ergonomically designed and easy to operate, just like a mobile device. The input/output terminals and keybord layout are arranged so that it can be operated in hands-on mode even when recording data.
Easy operation and device setup


Parameters in the AMP settings menu can be easily changed whilst viewing the waveform.

AMP parameter setting screen
TOP
Easy application software
Easy connection to PC
The GL220 can be controlled by a PC if connected by USB cable, allowing transfer of data to a PC in real-time.
http://www.graphteccorp.com/instruments/gl220/images/easy_application_01.jpg

If you need to move large data files to your PC then the GL220 can emulate an external USB drive for quick data transfer.
http://www.graphteccorp.com/instruments/gl220/images/easy_application_02.jpg

Up to 10 units can be connected to 1 PC. Measurements can be performed simultaneously or independently.
http://www.graphteccorp.com/instruments/gl220/images/easy_application_03.jpg
Various measurement screens
Select from 4 screens such as the Y-T (waveform + digital), Y-T (large waveform), digital view and report view to display measurements in real time. The direct-Excel function enables captured data to be written directly to an Excel file.


Waveform (Y-T) display

Digital display

Report display

Direct-Excel display

Substantial data replay screens
Three screens such as the Y-T (waveform), digital and the X-Y graph for specified data are available to view measurements in replay mode. The maximum, minimum, average and peak-to-peak vales between cursors are indicated in the digital display screen.


Waveform (Y-T) display

Digital display

X-Y (specified data) display

Simple configuration screens
The number of configuration screens has been reduced to five. Parameters can be set easily while viewing measured waveforms.

AMP parameter setting screen
Useful functions
Post-process your captured data with useful functions for arithmetic calculation, statistical calculation, search and file format conversion.
Useful functions
TOP
Other features
Can be used with 3 types of power source
Chose from AC supply, DC supply or the optional battery pack which enables 6 hours*7 of continuous measurement. The power source is automatically switched to the battery pack when the AC power supply is interupted. If the capacity of the battery pack goes low then measurement is automatically terminated and the captured data file is closed and protected.
*7:
DC power drive cable and battery pack are optional extras. Measuring time by using the battery pack varies on the conditions.
Alarm output function
Alarm signals can be output when alarm conditions occur. Four alarm output ports are fitted.*8
*8:
The Logic/alarm cable, (B-513 option), is needed to connect the alarm output ports.
Calculation function
Measured data can be compared with other channels in real-time. Four arithmetic functions can be selected. The calculation result is saved as measured data when the built-in memory or the USB memory stick is selected as the destination for the captured data.
GL220
Technical Specs & Details

 

 

GL220 main unit specifications


Item

Description

Number of analog input channels

10 ch

External input/output

Input *1

Trigger or Sampling input 1 ch, Logic or Pulse input 4 ch

Output *1

Alarm output 4 ch

Sampling interval

10 ms to 1 h (in 10ms to 50ms, voltage only and limited channel), External

Time scale

1 sec to 24 hour /division

Trigger function

Action

Start or stop capturing data by the trigger

Source

Start: Off, Input signal, Alarm, External *1 , Clock, Week or Time

Stop: Off, Input signal, Alarm, External *1 , Clock, Week or Time

Combination

OR or AND condition at the level of signal or edge of signal

Condition

Analog: Rising, Falling, Window-in, Window-out

Pulse: Rising, Falling, Window-in, Window-out

Logic: Rising or Falling

Alarm function

Detecting method

Level or edge of signal

Condition

Analog: Rising, Falling, Window-in, Window-out

Pulse: Rising, Falling, Window-in, Window-out

Logic: Rising, Falling

Alarm output *1

4 channels, Output type: Open collector (pull-up resistor 10 kΩ)

Pulse input function *1

Accumulating count mode

Accumulating the number of pulses from the start of measurement
Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S.

Instant count mode

Counting the number of pulses per sampling interval
Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S.

Rotation count (RPM) mode

Counting the number of pulses per second and then it is converted to RPM
Range: 50 rpm, 500 rpm, 5 krpm, 50 krpm, 500 krpm, 5 Mrpm, 50 Mrpm, 500 Mrpm /F.S.

Max. input pulse rate

50 k pulses/sec or 50k counts per sampling interval, 16 bits counter is used

Calculation function

Between channels

Addition, Subtraction, Multiplication and Division for analog input

Statistical

Select two calculations from Average, Peak, Max., Min., RMS

Search function

Search for analog signal levels, values of logic or pulse or alarm point in captured data

Interface to PC

USB (Full speed)

Storage device

Built-in Flash memory (2 giga-bytes), USB memory device *2

Data saving function

Captured data

Direct saving of data into built-in Flash memory or USB memory device

Others

Setting conditions, Screen copy

Ring capturing mode

Function: ON/OFF, Number of capturing point: 1,000 to 2,000,000
(Size of the capture data will be limited to 1/3 of available memory)

USB memory device emulation

USB Memory emulation mode (Transfer or delete the file in built-in memory)

Engineering scale function

Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output).

Display

Size

4.3 inch TFT color LCD (WQVGA: 480 x 272 dots)

Formats

Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital

Operating environment

0 to 45 °C, 5 to 85 %RH
(When operating with battery pack 0 to 40 °C, charging battery 15 to 35 °C)

Power source

AC adapter (100 to 240 V, 50/60 Hz), DC power (8.5 to 24 V DC, max. 26.4 V) *3 ,
Battery pack *3

Power consumption

29 VA or lower (when operating with AC adapter, displaying LCD)

External dimensions (W×D×H)

approx. 194 x 117 x 42 mm

Weight

approx. 520 g (Excluding AC adapter and battery pack)

*1
Logic alarm cable (B-513) option is required.
Input signal of External sampling, Logic, Pulse; Maximum voltage: 24 V, Threshold: approx. 2.5 V, Hysteresis: approx. 0.5 V.
*2
Size of the USB memory device is unlimited. Maximum file size is limited to 2GB.
*3
DC drive cable (B-514) or battery pack (B-517) option is required.
Analog input specifications


Item

Description

Type of input terminal

Screw terminal (M3 screw)

Input method

Scans by the photo-MOS-relay, all channels isolated, balanced input

Measurement range

Voltage

20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, and 1-5 V /F.S.

Temperature

Thermocouple: K, J, E, T, R, S, B, N, and W (WRe5-26)

Humidity

0 to 100% (using humidity sensor (B-530 optional), power is supplied to only one sensor)

Filter

Off, 2, 5, 10, 20, 40 (moving average in selected number)

Measurement accuracy *4

Voltage

0.1 % of F.S.

Temperature

Thermocouple

Measurement range

Measurement Accuracy

R/S

0 °C ≤ TS ≤ 100 °C
100 °C < TS ≤ 300 °C
R: 300 °C < TS ≤ 1600 °C
S: 300 °C < TS ≤ 1760 °C

± 5.2 °C
± 3.0 °C
± (0.05 % of reading + 2.0 °C)
± (0.05 % of reading + 2.0 °C)

B

400 °C ≤ TS ≤ 600 °C
600 °C < TS ≤ 1820 °C

± 3.5 °C
± (0.05 % of reading + 2.0 °C)

K

-200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 1370 °C

± (0.05 % of reading + 2.0 °C)
± (0.05 % of reading + 1.0 °C)

E

-200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 800 °C

± (0.05 % of reading + 2.0 °C)
± (0.05 % of reading + 1.0 °C)

T

-200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 400 °C

± (0.1 % of reading + 1.5 °C)
± (0.1 % of reading + 0.5 °C)

J

-200 °C ≤ TS ≤ -100 °C
-100 °C < TS ≤ 100 °C
100 °C < TS ≤ 1100 °C

± 2.7 °C
± 1.7 °C
± (0.05 % of reading + 1.0 °C)

N

0 °C ≤ TS ≤ 1300 °C

± (0.1 % of reading + 1.0 °C)

W

0 °C ≤ TS ≤ 2000 °C

± (0.1 % of reading + 1.5 °C)

 

Reference Junction Compensation (R.J.C.): ±0.5 °C

A/D converter

ΣΔ type, 16 bits (effective resolution: 1/40,000 of measuring full range)

Maximum input voltage

Between + / - terminal

60 V p-p

Between channels

60 V p-p

Between channel / GND

60 V p-p

Withstand voltage

Between channels

350 V p-p (1 minute)

Between channel(-)/ GND

350 V p-p (1 minute)

*4
Subject to the following conditions;
• Room Temperature is 23°C ±5°C.
• When 30 minute or more have elapsed after power was turned on.
• Filter is set to 10.
• Sampling rate is set to 1s with 10 channels.
• GND terminal is connected to the ground.
Software specifications


Item

Description

Supported OS

Windows XP / Vista / 7 (32 bits and 64 bits edition)

Functions

Control GL220, Real-time data capture, Replay data, Data format conversion

GL220 settings control

Input settings, Memory settings, Alarm settings, Trigger settings

Captured data

Transfers data in real-time (in binary or CSV format), saved data in GL220 or the USB memory

Displayed information

Analog waveforms, Logic waveforms, Pulse waveforms, Digital values

Display modes

Y-T waveforms, Digital values, Report, X-Y graph (specified period of data, data replay only)

Warning functions

Sends E-mail to the specified address when the alarm occurred

File format conversions

Converts the specified period data or all data to the CSV format (thinning function is available)

Report functions

Creates a daily or monthly report automatically (can also export directly to Excel)

Displayed Max. Min.

Displays the maximum, minimum and current value in measurement

Standard accessories


Item

Description

Quantity

AC adapter

100 to 240 V AC, 50 / 60 Hz (with specified type of power cord)

1 set

CD-ROM

User’s manual (PDF format), Application software

1 piece

Quick Start Guide

 

1 copy

 

GL220
Graphtec Media & Top Quality Supplies

 
 

Options and accessories


Item

Model number

Remarks

Logic alarm cable

B-513

2 m long (no clip on end of cable)

DC drive cable

B-514

2 m long (no clip on end of cable)

Battery pack

B-517

1 piece (7.4 V 2200 mAh, 17Wh)

Humidity sensor*

B-530

3 m long (with power plug)

Battery pack
(B-517)
http://www.graphteccorp.com/instruments/gl220/images/B-517.gif

Logic alarm cable
(B-513)
http://www.graphteccorp.com/instruments/gl220/images/B-513.gif

DC drive cable
(B-514)
http://www.graphteccorp.com/instruments/gl220/images/B-514.gif

Humidity sensor
(B-530)
http://www.graphteccorp.com/instruments/gl220/images/B-530.gif

 

 

New Products 2010!

 

KL Office:
See Map

207, Lvl 2, Blok B3, Leisure Commerce Square, Jln PJS8/9, 46150 Petaling Jaya, Selangor, MY. (Kurnia Building,Sunway)
Tel(KL) :
+60 3- 78762460, 78762463
Fax(KL):
+60 3-78762454

Office hour (KL):Mon-Fri 9am-6pm, Sat 9am-1pm


(Please call our office to make an appointment if you decide to come)

 

 

Johor Office :
See Map
Suite 3, 9th Floor, Wisma Sing Long, 9 Jln Zabedah, 83000 Batu Pahat, Johor, MY.
Tel(Johor) :
+60 7-4352540,4355540 Fax(Johor):
+60 7-4347299

Email: This e-mail address is being protected from spam bots, you need JavaScript enabled to view it This e-mail address is being protected from spam bots, you need JavaScript enabled to view it

Office hour(Johor): Mon-Fri 9am to 6pm, Sat 9am-1pm


"How can we help you?"
Salesperson:Siti,Hui Hui ,Steven,Yusof, Syafiq


Customer Service(Overseas):
+00607-4352540 +00607-4355540


Email

( This e-mail address is being protected from spam bots, you need JavaScript enabled to view it )

Enquiry FormThis email address is being protected from spam bots, you need Javascript enabled to view it

     
   

Close on Sunday

Over 2,200 customers served! You can't be wrong for choosing KKInstruments!

 

awards & achievements

We’re No. 1 In Malaysia!

Put awards & achievements aside, we are just here to continue serving you our very best!

 

Latest Products

Login Form






Lost Password?
Enquiry Form
Title
Invalid Input
Purpose
Invalid Input
Contact Person (*)
Please type your full name.
Company
Invalid Input
Handphone
Invalid Input
Office Tel
Invalid Input
Office Fax
Invalid Input
E-mail (*)
Invalid email address.
Brand 1
Invalid Input
Model 1
Invalid Input
Brand 2
Invalid Input
Model 2
Invalid Input
Question
Invalid Input
Photo/File
Invalid Input
.gif .pdf .jpg .jpeg .doc .xls
You may upload any photo/file and send it to us.
  
2010 KKInstruments - Measuring instruments that should your needs
Joomla Templates by JoomlaShack Joomla Templates