"My third deal with them. Price acceptable. Service Excellent. They have helped us to source several products that make it possible for us to fulfill our orders before deadline! Beginning I was a bit worry but they made it! My Customer-Telekom are happy with all the products! Will buy again! - As-per
"Good Service" SAAG GROUP
DELIVER BY
GRA002-GL820 20 multi-channel logger (up to 200ch)
Includes Software, 100 to 240 VAC Adapter and User Manual
Huge 2GB Flash Memory,
modular system allows expansion up to 200 channels
Modular system allows expansion up to 200 channels
The standard configuration has 20 analogue input channels. It can be expanded up to 200 channels by adding optional 20 channelextension terminal kits.
All channels are isolated, each with multifunction input
Isolated channels, each with multifunction input
It contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. The GL820s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage.
Maximum sampling rate of up to 10ms
Provides faster sampling rates for voltage measurements. Can achieve 10ms sampling interval when limiting the number of channels in use.
Sampling interval
10ms
20ms
50ms
100ms
200ms
500ms
1s
2s
Channels
1
2
5
10
20
50
100
200
Measurement*2
Voltage
X
X
X
X
X
X
X
X
Temp.
N/A
N/A
N/A
X
X
X
X
X
X:
selection is available, N/A: selection is not available
*2:
For humidity measurements, the 0-1 V range and scaling function are used to display results directly in Relative Humidity. Sampling rate limitations are same as those for voltage measurement.
External sampling function
Captured data can be synchronized with external timing signals when the external sampling rate function is used.*3
*3:
The Logic/alarm cable, (B-513 option), is needed to connect the alarm output ports. TOP
Huge built-in 2GB Flash memory
Built-in 2GB Flash Memory for reliable long term measurement
The 2GB Flash Memory enables secure long term data measurement without using an external storage device. Data is retained even when power is turned off because flash memory is used.
Capturing time*4 (20 Analogue channels being used.)
[unit: days]
Sampling interval
10ms*5
50ms*5
100ms*5
200ms
500ms
1s
2s
Built-in 2GB Flash Memory
29
72
89
101
253
506
5,068
512MB USB memory stick*6
7
18
22
25
64
129
1,294
*4:
The above figures are approximate.
*5:
The sampling rate is limited by the number of channels in use. (10ms: 1ch, 50ms: 5ch, 100ms: 10ch)
*6:
Standard USB memory devices without high-end functions such as fingerprint recognition are required.
Ring memory function
The most recent data is saved when internal memory or external memory is configured in ring memory mode. Captured data size in ring memory mode is limited to 1/3 of available memory.
Hot-swappable USB memory sticks
Also supports popular USB memory sticks for external storage. The GL820 saves measured data directly to USB memory sticks. USB memory sticks can be replaced during measurement without data loss. TOP
Large easy-to-read 5.7-inch wide TFT color LCD
Utilises a bright clear 5.7-inch wide TFT color LCD monitor (VGA: 640 x 480 dots). Makes it easy to read data in waveform or digital form and to check your measurement parameter settings. The background color of the screen can be set to black or white.
PC-friendly, supports USB memory stick, has USB and LAN ports
Supports USB memory devices
Captured data can be saved directly to USB memory sticks when these are chosen for external storage.
Easy connection to PC via USB or Ethernet
The GL820 can be controlled by a PC if connected by USB cable, allowing transfer of data to a PC in real-time. If you need to move large data files to your PC then the GL820 can emulate an external USB drive for quick data transfer.
The WEB & FTP server function, FTP client-server function and NTP client function are supported when the GL820 is connected to the LAN via the Ethernet port. TOP
Easy application software
Easy connection to PC
The GL820 can be controlled by a PC if connected by USB cable, allowing transfer of data to a PC in real-time.
If you need to move large data files to your PC then the GL820 can emulate an external USB drive for quick data transfer.
Up to 10 units or 500 channels can be connected to 1 PC through LAN or USB. Measurements can be performed simultaneously or independently.
Various measurement screens
Select from 4 screens such as the Y-T (waveform + digital), Y-T (large waveform), digital view and report view to display measurements in real time.
The direct-Excel function enables captured data to be written directly to an Excel file.
Informative data replay screens
Three screens are available to view measurements in replay mode. The Y-T (waveform) display, the digital display and the X-Y graph can be selected to show your specified data. The maximum, minimum, average and peak-to-peak values between cursors are shown when using the digital display screen.
Simple configuration screens
The number of configuration screens has been reduced to five. Parameters can be set easily while viewing measured waveforms.
Useful functions
Post-process your captured data with useful functions for arithmetic calculation, statistical calculation, search and file format conversion.
The configuration of CSV file can be specified.
Alarm signals can be output when alarm conditions occur. Four alarm output ports are fitted.*7
*7:
The Logic/alarm cable, (B-513 option), is needed to connect the alarm output ports.
Alarm warnings can be sent via E-mail when computer is connected to LAN.
Can be used with 3 types of power source
Chose from AC supply, DC supply or the optional battery pack which enables 6 hours*8 of continuous measurement. The power source is automatically switched to the battery pack when the AC power supply is interupted. If the capacity of the battery pack goes low then measurement is automatically terminated and the captured data file is closed and protected.
*8:
DC power drive cable and battery pack are optional extras. Measuring time by using the battery pack varies on the conditions.
GL820
GL820 Main Unit Specifications
item
Description
Number of analog input channels
20 ch, Expandable up to 200 ch by unit of 20 ch
External input output
Input *1
Trigger or Sampling input 1ch, Logic or Pulse input 4 ch
Output *1
Alarm output 4 ch
Sampling interval
10 ms to 1 h (in 10 ms to 50 ms, voltage only and limited channel), External
Time scale
1 sec to 24 hour/division
Trigger function
Action
Start or stop capturing data by the trigger
Source
Start: Off, Input signal, Alarm, External *1, Clock, Week or Time
Stop: Off, Input signal, Alarm, External *1, Clock, Week or Time
Combination
OR or AND condition at the level of signal or edge of signal
Condition
Analog: Rising, Falling, Window-in, Window-out
Pulse: Rising, Falling, Window-in, Window-out
Logic: Rising, Falling
Alarm function
Detecting method
Level or edge of signal
Condition
Analog: Rising, Falling, Window-in, Window-out
Pulse: Rising, Falling, Window-in, Window-out
Logic: Rising, Falling
Alarm output *1
4 channels, Output type: Open collector (pulled-up to 5 V by resistor 10 kΩ)
Pulse input function *1
Accumulating count mode
Accumulating the number of pulses from the start of measurement
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S.
Instant count mode
Counting the number of pulses per sampling interval
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S.
Rotation count (RPM) mode
Counting the number of pulses per second and then it is converted to RPM
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M rpm /F.S.
Max. input pulse rate
50k pulses/sec or 50k counts per sampling interval (16 bits counter is used)
Calculation function
Between channels
Addition, Subtraction, Multiplication and Division for analog input
Statistical
Select two calculations from Average, Peak, Max., Min., RMS
Search function
Search for analog signal levels, values of logic or pulse or alarm point in captured data
Interface to PC
Ethernet (10 BASE-T/100 BASE-TX), USB (Full speed)
Storage device
Built-in Flash memory (2 giga-bytes), USB memory device *2
Data saving function
Captured data
Direct saving of data into built-in Flash memory or USB memory device
Others
Setting conditions, Screen copy
Ring capturing mode
Function: ON/OFF, Number of capturing point: 1000 to 2000000 (size of the capture data will be limited to 1/3 of available memory when in Ring Mode)
USB memory device emulation
USB Memory emulation mode (Transfer or delete the file in built-in memory)
Engineering scale function
Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output).
Display
Size
5.7 inch TFT color LCD (VGA: 640 x 480 dots)
Formats
Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital
Operating environment
0 °C to 45°C, 5 % to 85 % RH
(When operating with battery pack 0 °C to 40 °C, charging battery 15 °C to 35°C)
Power source
AC adapter (100 V to 240 V, 50/60 Hz)
DC power (8.5 V to 24 V DC, max. 26.4 V)*3, Battery pack*3
Power consumption
32VA or lower
(When operating with AC adapter, displaying LCD, charging battery pack)
External dimensions (WxDxH)
approx. 232 x 152 x 50 mm
Weight
approx. 900 g (Excluding AC adapter and battery pack)
Software specifications
Item
Description
Supported OS
Windows XP / Vista / 7 (32 bits and 64 bits edition)
Functions
Control GL820, Real-time data capture, Replay data, Data format conversion
Transfers data in real-time (in binary or CSV format), saved data in GL820 or the USB memory
Displayed information
Analog waveforms, Logic waveforms, Pulse waveforms, Digital values
Display modes
Y-T waveforms, Digital values, Report, X-Y graph (specified period of data, data reply only)
Warning functions
Sends E-mail to the specified address when the alarms occur
File format conversions
Converts the specified period data or all data to the CSV format (thinning function is available)
Report functions
Creates the daily or monthly report automatically (can also export directly to Excel)
Standard accessories
Item
Description
Quantity
AC adapter
100 V to 240 V AC, 50/60 Hz (with specified type of power cord)
1set
CD-ROM
User's manual (PDF format), Application software
1piece
Quick Start Guide
1copy
Analog input specifications
Item
Description
Type of input terminal
Screw terminal (M3 screw)
input method
Scans by the photo-MOS-relay, all channels isolated, balanced input
Measurement range
Voltage Temperature
20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, and 1-5 V /F.S.
Thermocouple: K, J, E, T, R, S, N, and W (WRe5-26)
Resistance Temperature Detectors (RTDs): Pt100, JPt100 (JIS), Pt1000 (IEC751)
Humidity
0 to 100%
(using humidity sensor (B-530 optional), power is supplied to only one sensor)
Filter
Off, 2, 5, 10, 20, 40 (moving average in selected number)
Measurement accuracy *4
Voltage
0.1% of F.S.
Temperature
Thermocouple
Measurement range
Measurement accuracy
R/S
0 °C ≦ TS ≦ 100 °C
100 °C ≦ TS ≦ 300 °C
R: 300 °C ≦ TS ≦ 1600 °C
S: 300 °C ≦ TS ≦ 1760 °C
±5.2 °C
±3.0 °C
±(0.05 % of reading +2.0 °C)
±(0.05 % of reading +2.0 °C)
B
400 °C ≦ TS ≦ 600 °C
600 °C ≦ TS ≦ 1820 °C
±3.5 °C
±(0.05% of reading +2.0 °C)
K
-200 °C ≦ TS ≦ -100 °C
-100 °C ≦ TS ≦ 1370 °C
±(0.05 % of reading +2.0 °C)
±(0.05 % of reading +1.0 °C)
E
-200 °C ≦ TS ≦ -100 °C
-100 °C ≦ TS ≦ 800 °C
±(0.05 % of reading +2.0 °C)
±(0.05 % of reading +1.0 °C)
T
-200 °C ≦ TS ≦ -100 °C
-100 °C ≦ TS ≦ 400 °C
±(0.1 % of reading +1.5 °C)
±(0.1 % of reading +0.5 °C)
J
-200 °C ≦ TS ≦ -100 °C
-100 °C ≦ TS ≦ 100 °C
100 °C ≦ TS ≦ 1100 °C
±2.7 °C
±1.7 °C
±(0.05 % of reading +1.0 °C)
N
0 °C ≦ TS ≦ 1300 °C
±(0.1 % of reading +1.0 °C)
W
0 °C ≦ TS ≦ 2000 °C
±(0.1 % of reading +1.5 °C)
Reference Junction Compensation (R.J.C.): ±0.5 °C
RTD
Measurement range
Measurement accuracy
Pt100
-200 °C to 850 °C (FS=1050 °C)
±1.0 °C
JPt100
-200 °C to 500 °C (FS=700 °C)
±0.8 °C
Pt1000
-200 °C to 500 °C (FS=700 °C)
±0.8 °C
A/D Converter
ΣΔtype, 16 bits (effective resolution: 1/40000 of measuring full range)
Maximum input voltage
Between +/- terminal
60 Vp-p
Between channels
60 Vp-p
Between channels / GND
60 Vp-p
Withstand voltage
Between channels
350 Vp-p (1minute)
Between channels(-) / GND
350 Vp-p (1minute)
*1
Logic alarm cable (B-513) option is required.
Input signal of External sampling, Logic, Pulse; Maximum voltage: 24 V, Threshold: approx. 2.5 V, Hysteresis: approx. 0.5 V
*2
Size of the USB memory device is unlimited. Maximum file size is limited to 2 GB
*3
DC drive cable (B-514) or battery pack (B-517) option is required.
*4
Subject to the following conditions;
Room Temperature is 23 °C±5 °C
When 30 minutes or more have elapsed after power was turned on.
(Please call our office to make an appointment if you decide to come)
Johor Office : See Map Suite 3, 9th Floor, Wisma Sing Long, 9 Jln Zabedah, 83000 Batu Pahat, Johor, MY.
Tel(Johor) :
+60 7-4352540,4355540 Fax(Johor):
+60 7-4347299
Email:
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
Office hour(Johor): Mon-Fri 9am to 6pm, Sat 9am-1pm
"How can we help you?"
Salesperson:Siti,Hui Hui ,Steven,Yusof, Syafiq