"My third deal with them. Price acceptable. Service Excellent. They have helped us to source several products that make it possible for us to fulfill our orders before deadline! Beginning I was a bit worry but they made it! My Customer-Telekom are happy with all the products! Will buy again! - As-per
"Good Service" SAAG GROUP
DELIVER BY
RCD(ELCB) tester
RCD -10 (Made in Japan)
•
Measurement of RCD trip time
•
Measurement of trip out current
•
Remote Test
•
Voltage Measurement
•
Auto-detection of Contact voltage
•
Dust- and Water-proof
•
Backlight
•
Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
•
Measurement of trip out current
Measuring trip out current by varying current automatically.
•
Remote Test
Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
•
Voltage Measurement
Carrying out a constant measurement of voltage in the stand-by mode at each Range.
•
Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
•
Dust- and Water-proof
Dust- and Water-proof construction (designed to IEC60529 IP54).
•
Backlight
Facilitating working at dimly illuminated locations.
Measurement of RCD trip time - Measurement of trip out current
Range
×5
×1
×1/2
AUTO RAMP (mA)
Rated Voltage
100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current
15/30/50/100mA
15/30/50/100/200/500mA
15/30/50/100/200/500mA
Measuring range
Testing time
200ms
Testing time
2000ms
Testing time
2000ms
40%~110% of lΔn
(goes up by 5%)
Testing time
300ms × 15steps
-20ºC~60ºC, relative humidity 85% (no condensation)
Withstand Voltage
AC3700V / 1 min. (between electrical circuit and enclosure)
Insulation resistance
50MΩ or more / 1000V (between electrical circuit and enclosure)
Sleep Function
(1)
Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2)
Backlight turns off in 1 minute after it lights up.
Power Source
DC 12V / Size AA battery R6P (SUM-3) × 8 pcs.
Dimension
186(L)×167(W)×89(D)mm
Weight
Approx. 965g (including batteries)
Possible number of Measurements
1200 times or more
(measure every 30 seconds at ×1/2 Range, lΔn=100mA)
RCD-06 (japan)
•
Custom microprocessor controlled for highest accuracy and reliability.
•
3 LEDs for checking correct wiring status.
•
0 and 180 degree phase angle switch permits quick tests and consistent readings.
•
Digital read-out of tripping time.
•
Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
•
Large custom digital display readout.
•
Visual indication of reversed phase and neutral wiring at socket.
•
Designed to IP54 Rating.
•
Complies with IEC61557
•
Test of a large kind of RCD's:
Standard, Selective, AC and A (DC sensitive breakers)
•
Custom microprocessor controlled for highest accuracy and reliability.
•
3 LEDs for checking correct wiring status.
•
0 and 180 degree phase angle switch permits quick tests and consistent readings.
•
Digital read-out of tripping time.
•
Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
•
Large custom digital display readout.
•
Visual indication of reversed phase and neutral wiring at socket.
•
Designed to IP54 Rating.
•
Complies with IEC61557
•
Test of a large kind of RCD's:
Standard, Selective, AC and A
(DC sensitive breakers)
|Molded plug test leads
|Pouch for test leads
|Shoulder Strap
|Instruction Manual
Optional
|7121(Distribution board test leads)
RCD-02 (japan)
•
Accurate digital readout of tripping time.
•
Two neon lamps give quick check for correct wiring.
•
Compact, lightweight and simple to operate.
•
Zero cross circuitry permits testing at 0 and 180 degree portion of sine wave. At these two tests minimum (best) and maximum (worst) trip times will be displayed.
•
Accurate digital readout of tripping time.
•
Two neon lamps give quick check for correct wiring.
•
Compact, lightweight and simple to operate.
•
Zero cross circuitry permits testing at 0 and 180 degree portion of sine wave. At these two tests minimum (best) and maximum (worst) trip times will be displayed.
(Please call our office to make an appointment if you decide to come)
Johor Office : See Map Suite 3, 9th Floor, Wisma Sing Long, 9 Jln Zabedah, 83000 Batu Pahat, Johor, MY.
Tel(Johor) :
+60 7-4352540,4355540 Fax(Johor):
+60 7-4347299
Email:
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
This e-mail address is being protected from spam bots, you need JavaScript enabled to view it
Office hour(Johor): Mon-Fri 9am to 6pm, Sat 9am-1pm
"How can we help you?"
Salesperson:Siti,Hui Hui ,Steven,Yusof, Syafiq